6
OWNERS MANUAL
Make sure you have met the following installation conditions and clearances:
•
Compressor needs to be installed in a clean, dry location.
•
Compressor needs to be protected from dirt and moisture and from the outdoor environment such as rain,
snow, flooding, etc.
•
Ambient air temperature must not exceed 104° F (40°C).
•
Adequate ventilation and cooling air (air flow across the compressor) must be provided to keep the
compressor from overheating and causing damage. The included fan has been provided for this purpose.
•
Included is a simple bracket to allow easy mounting to a wall, floor or bench.
After the proper location has been determined, use the following diagrams to complete the installation:
120V compressors are supplied with a NEMA 5-15 plug. 240V compressors are supplied with flying leads. The
leads can be hard-wired into 240V service or an
appropriate plug can be installed.
Kasco recommends that the site service providing
system power have a human-rated Ground Fault
Circuit Interrupter outlet (120V) or human-rated
Ground Fault breaker (240V) for your protection.
Contact a licensed electrician to install 120 or 240
volts (depending on model), single phase power at the
compressor location with appropriate human-rated
ground fault protection.
Base Mount Cabinet Installation:
RA(H)1-NC
RA(H)1-NC
RA(H)3-NC