Troubleshooting Tips

Troubleshooting tips - light kit

Problem

Possible Cause

Likely Remedy

Power is off or disconnected

Ensure control panel is connected to the electrical  circuit.  Verify circuit breakers, timers, and/or 
interlock switches are turned on and functional. Refer to your owners manual that was provided with 
the fountian. 

C-25 control panel:  

The control panel has a photo eye on the left side of the enclosure exterior.  This photo eye measures 
ambient light.  To activate, the photo eye must not measure any ambient light for at least several 
minutes.  Also, the C-25 timer must be turned on (fountain operating) to allow the light circuit to 
energize.  Covering the photo eye with black electrical tape will activate the photo eye for testing.

C-85, or C-95 control panel with GFCI outlet and photo eye control:

The control panel has a photo eye on the left side of the enclosure exterior.  This photo eye measures 
ambient light.  To activate, the photo eye must not measure any ambient light for at least several 
minutes.  Also, the fountain timer must be turned on (fountain operating) to allow the light circuit to 
energize.  Covering the photo eye with black electrical tape will activate the photo eye for testing.  
While the photo eye is covered, the GFCI outlet can be reset if tripped.  

Timer not set properly

C-85, or C-95 control panel (and all 3phase fountain control panels) with terminal connections 
and timer control for light kit:  

The control panel has a second timer for controlling the lights (No photo eye).  Ensure the light timer 
is set to operate the lights.  The timer has a built in Hand-Off-Auto swith.  Ensure the switch is set 
properly.  
Ensure the fountain is turned on.  The light timer will not energize the light kit unless the fountain 
circuit is energized.

C-25 control panel:

Reset the GFCI.  If the GFCI does not reset it could be a ground fault in the fountain wiring, or the light 
kit wiring.  Unplug both the fountain and light kit and reset the GFCI.  If it resets, plug fountain then 
light kit back in and see which one trips the GFCI.  If the GFCI does not reset with both unplugged, 
then the GFCI may be defective.

C-85, or C-95 control panel with GFCI outlet and photo eye control:

To reset the GFCI outlet the fountain timer must be turned on, and the photo eye must be activated. 
(black electrical tape can be wrapped around the photo eye to activate it).  Once these are on, the 
GFCI reset button can be pressed.  (unplug the light kit prior).  Plug the light kit in and see if it 
operates.  If the GFCI trips again then the light kit may be damaged.  If the GFCI does not reset (with 
light kit unplugged) then it may be defective or the photo eye is not activated to send power to the 
outlet. 

C-85, or C-95 control panel with terminal connections and timer control for light kit:

For panels with a GFCB (ground fault circuit breaker) and timer controlled lights, simply reset the two 
pole breaker. This will turn the fountain and light kit back on if the timers are set to on! If it trips again, 
disconnect the light kit from the terminals and reset.  WARNING! you must turn off power to the panel 
before disconnecting any wiring from the terminals!  If the breaker trips with the light kit 
disconnected, then disconnect the fountain as well and reset.  If the breaker continues to trip it may 
be a defective GFCB.  If the breaker resets, then reconnect the fountain then the light kit to see which 
one trips the GFCB.  

3phase fountain control panels:

3phase fountain panels have a ground fault sensing module that will trip if either the light kit or 
fountain has a ground fault.  To reset the module, simply press the reset button in the panel.  This will 
turn the fountain and light kit back on if the timers are set to on!   If it trips again, disconnect the light 
kit from the terminals and reset.  WARNING! you must turn off power to the panel before 
disconnecting any wiring from the terminals!  If the GFI module trips with the light kit disconnected, 
then disconnect the fountain as well and reset.  If the GFI module continues to trip it may be a 
defective module or an internal wiring issue with the panel.  If the module resets, then reconnect the 
fountain then the light kit to see which one trips the module.  

Light work.  However, 

they are not as bright as 

when first installed.

Dirty lenses

Turn of power to the control panel and disconnect power cords to the fountain and the light kit.  
Bring the fountain to the shore and inspect the light lenses.  Over time, algae growth and hard water 
deposits on the lenses can block light output.  Clean the lenses with a soft brush and the light should 
be bright again.

Not dark enough for photo 

eye to activate

Light kit is installed and 

wired, but will not turn 

on.

GFCI is tripped

The following is provided to help diagnose a probable source of trouble.  It is a guideline only and may not show all causes for all problems.  For additional 
troubleshooting help contact your local distributor or visit www.kascomarine.com for additional help.

NOTE:  you may need to refer to your owners manual that was provided with your fountain for additional control panel settings and adjustments.

Содержание LED3S19-050

Страница 1: ...ructions pg3 Instructions For Mounting LED6S19 pg5 Maintenance Recommendations pg5 Warranty Policy pg6 Troubleshooting Tips pg8 Replacement Parts pg9 Customer Repair Form pg10 Registration Information pg12 Rev 02 01 16 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com Submersible luminaire E478088 LISTED ...

Страница 2: ...dangerous situation for the operator Extreme caution should be used around water es pecially cold water as in Spring Fall and Winter which poses a hazard itself NEVER lift or drag the fountain or light kit by the power cords If you need to pull the unit to the side of the pond use the anchoring ropes Do not use waders in ponds lakes that are deep with drop offs drastic slopes or soft bottom mate r...

Страница 3: ... mounting brackets Fig 4 Stainless Steel Flat Washer 6 Stainless Steel Nut 6 x Stainless Steel Bolt 12 x 1 Stainless Steel Bolt 6 Nylon Cable Ties 12 Lower Float Brackets 6 3 8 Stainless Steel Flat Washers 3 TOOLS SUPPLIES NEEDED Two 7 16 wrenches or one wrench a 7 16 socket with driver Two 9 16 wrenches or one wrench a 9 16 socket with driver Wire Cutter for trimming cable ties LED3S19 Assembly I...

Страница 4: ...ets Fig 9 6 Using the cable ties tie each ixture cord to bottom leg of mounting brackets using the holes provided The will act as a strain relief and will keep the cord from being damaged by the fountain and balance the unit properly Next cable tie the main power cord to the loat as shown in Fig 5 Fig 5 7 Upon installation of the assembled unit connect your LED light kit to your ield installed GFC...

Страница 5: ...to electrical leaks in the equipment If you have repeat consistent trips of the ground fault device the equipment should be disconnected and removed from the water The power cord should be inspected for dam age and you should contact your distributor or call Kasco 6 Using the cable ties tie each ixture cord to bottom leg of mounting brackets using the holes provided The will act as a strain relief...

Страница 6: ...possible for any reduction or variation in performance If a change in performance is ob served the equipment should be disconnected from power and inspected WINTER STORAGE In regions where there is signiicant freezing in the wintertime the fountain and light kit should be removed from the water to protect them from the expan sion pressure of the ice In many areas fountains will keep some amount of...

Страница 7: ... restored as closely as possible to the condition in which it was received and shipped at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned to the customer and billed C O D unless otherwise directed Kasco Marine also accepts Visa and MasterCard credit card payments Kasco Marine will call for credit card information upon completion of the est...

Страница 8: ...g the light kit in and see if it operates If the GFCI trips again then the light kit may be damaged If the GFCI does not reset with light kit unplugged then it may be defective or the photo eye is not activated to send power to the outlet C 85 or C 95 control panel with terminal connections and timer control for light kit For panels with a GFCB ground fault circuit breaker and timer controlled lig...

Страница 9: ...W 1 4 20x1 2 2 2 840537 LOCK WASHER 1 4 2 3 346065 BRACKET S S LED MOUNTING 1 3 MODEL LEDxS19 xxx 19 WATT LED LIGHT FIXTURE REPLACEMENT PARTS 1 2 DO NOT ATTEMPT TO OPEN CONTACT KASCO MARINE FOR INSTRUCTIONS REGARDING SERVICE OR REPAIR Replacement Parts ...

Страница 10: ...ed for warranty repair Do not ship the control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number ___________________ City ____________________ Email Address ______________________ State _____________________ Zip Code ____________...

Страница 11: ...11 ...

Страница 12: ...________ Serial Ex 2101LEDS3001 ____________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884050 ...

Отзывы: