manualshive.com logo in svg
background image

AQUATICLEAR CIRCULATOR MANUAL

9

WARRANTY

Warranty period: 2400EC, 3400EC = 2 years

Kasco® Marine, Inc. warrants this equipment to be free from defects in material or workmanship (except 

for the ropes, power cord, and propeller) under normal use and service. The Kasco Marine, Inc. obligation 

under this warranty is limited to replacing or repairing free of charge any defective part within the warranty 

period. Customer shall pay shipping charges for returning the unit to Kasco or an Authorized Repair Center. 

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND ANY OTHER OBLI-

GATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE, INC. AND IN NO EVENT SHALL KASCO 

MARINE, INC. BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES. 

Warranty is void if: 

•  The equipment is not maintained properly according to the Maintenance Recommendations supplied in 

this manual. 

•  The equipment is returned for repair without the power cord or if the unit, control box, or power cord 

are altered in any way from original shipment. Cuts in the power cord are not covered under warranty. 

•  The equipment is not used with the supplied GFCI control box. 

•  The equipment is damaged by unauthorized tampering. 

• 

The sacrificial anode around the propeller shaft shows significant deterioration. (The anode must be 

inspected periodically and replaced if necessary.) 

Warranty Claim Procedure

Warranty period is established by the original receipt. For efficient service, please register the unit online 

www.kascomarine.com

.

Once warranty coverage has been established, you may send the unit to Kasco for evaluation and repair.

Kasco only accepts complete assemblies for warranty repair. We must receive the power cord and 

all other components with the motor as originally assembled without the float or mount. Kasco will 

bill the customer to replace any missing parts necessary for repair. It is not necessary to return the 

control panel, mount, or other parts with the motor assembly, unless specifically requested by a 

Kasco representative.

Please attach a repair form with the shipment. The repair form must include a name, physical 
address (for return delivery of the repaired unit), daytime phone number, and an e-mail address 
for correspondence regarding the warranty claim.

Any expedited shipping method for the return of the unit is at the customer’s expense. Kasco will 
return units repaired under warranty at our expense via ground freight within the continental 
United States.

Содержание AquatiClear 2400EC

Страница 1: ...ott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 CIRCULATOR Operation Maintenance Manual Document 884149 Version 2021 1 0 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 AquatiClear 50 Hz ...

Страница 2: ...cal and or moving equipment NEVER run the unit out of water NEVER lift or drag the equipment by the power cord Follow all boating safety rules and regulations during installation Single phase units are supplied with an internal grounding conductor and a grounding type attachment plug To reduce the risk of electrical shock be certain that the unit is plugged into a protected circuit Control panels ...

Страница 3: ...arine backs each AquatiClear unit with a 2 Year Warranty This warranty covers any and all manufacturer s defects within the warranty period from the date of purchase Use and Operation Kasco Circulators are designed and engineered for continuous duty Upon installation your Kasco AquatiClear is ready for immediate use Make sure to keep the motor housing clean from hard water deposits and or algae Mo...

Страница 4: ... 243410 B 1 2 washer 1 475642 C Propeller 2400EC 1 340135 C Propeller 3400EC 1 440435 D AquatiClear prop guard 1 993210 E 1 4 20 x 1 1 2 screw 3 475695 F Retaining clip 3 140312 G 1 4 20 nut 3 840538 H Sealed motor unit 1 N A I Prop stop 1 440630 J Sacrificial anode 1 243474 F A B D C E G H I J ...

Страница 5: ...The upper mount can be secured horizontally as shown above or vertically right allowing installation options for a variety of shoreline structures Easily lower angle and position units for proper water movement Mount to a dock piling wall or other in water property Packages include upper and lower mount assemblies pipe supplied by customer Float Mount Kasco s Horizontal Float suspends the unit in ...

Страница 6: ...n and above freezing temperatures During the offseason store the unit on its side to help prevent the seals from drying out Cleaning Remove circulators from the water at least once per year to clean the exterior of the system especially the stainless steel motor housing can to avoid build up of algae calcium or other materials This buildup can lead to overheating In warmer regions Kasco recommends...

Страница 7: ...hese symptoms the unit should be unplugged immediately because the thermal overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the cause of the problem The problem could be low water levels build up on the unit preventing heat dissipation something inhibiting the free rotation of the shaft etc If somethi...

Страница 8: ...AQUATICLEAR CIRCULATOR MANUAL 8 SACRIFICIAL ANODE REPLACEMENT A B C 1 2 E F G 3 6 4 5 x 3 Tighten this nut first and proceed counterclockwise 7 ...

Страница 9: ...CI control box The equipment is damaged by unauthorized tampering The sacrificial anode around the propeller shaft shows significant deterioration The anode must be inspected periodically and replaced if necessary Warranty Claim Procedure Warranty period is established by the original receipt For efficient service please register the unit online www kascomarine com Once warranty coverage has been ...

Страница 10: ... Customer pre approves repair of the unit if costs are below a stated dollar amount Example Please repair if total is under 150 00 before shipping charges Kasco will recycle any unit we receive for estimate but which the customer declines to repair unless the customer specifies otherwise If the customer would like the product returned Kasco will return the unit to the condition in which we receive...

Страница 11: ...hemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the cust...

Отзывы: