manualshive.com logo in svg
background image

2

 

CAUTION

 NOTICE (NOTE)

These international safety symbols are used through-
out this manual to inform the end user, installer, and 
owner of important safety information and notices for 
safe and effective use of the equipment.

Important Safety Instructions

 CAUTION

Under NO circumstances should anyone 

• 

enter the water with the electrical equipment 
plugged in and/or in operation.  It is NEVER 
recommended to enter the water with the 
equipment in operation.
Caution should be used when dealing with any 

• 

electrical equipment with moving parts.
NEVER run the unit out of water.  It will 

• 

damage the seals and create a dangerous 
situation for the operator.
Extreme caution should be used around water, 

• 

especially cold water, such as in Spring, Fall, 
and Winter, which poses a hazard in and of 
itself.
NEVER lift or drag the unit by the power or 

• 

light cord.  If you need to pull the unit to the 
side of the pond, use the anchoring ropes.
Do not use waders in deep ponds/lakes or 

• 

ponds/lakes with drop-offs, drastic slopes, or 
soft bottom material.
Do not use boats that tip easily for fountain 

• 

installation, such as a canoe, and follow all 
boating safety rules and regulations, including 
wearing a PFD. (Personal Flotation Device)
The unit is supplied with an internal grounding 

• 

conductor.  To reduce the risk of electrical 
shock, be certain that the unit is plugged/
connected to an approved RCD (GFCI) 
protected circuit.  
A properly sized 3 phase motor control 

• 

(motor starter) with overload and short 
circuit protection must be provided at time of 
installation.
3 phase units (2.3, 3.3, 5.3) require a startup 

• 

test after wiring to ensure proper rotation of 
the impeller.  If the impeller is rotating in the 
opposite direction, the unit will not perform 
properly and internal damage to the unit may 
occur.  (See 3 phase startup procedure)
Means for disconnection must be incorporated 

• 

in the fi xed wiring in accordance with local 
and national wiring rules to prevent accidental 
start.
Consult a qualifi ed electrician for electrical 

• 

installation.

General description of equipment 

and function

Fountain/decorative aerator
Electrically driven submersible pump designed to im-
prove water quality with water movement and aeration 
in a decorative display.

Intended use and limits of use

Kasco equipment is only intended for specifi c uses as 
detailed in this owner’s manual.  Intentional misuse 
could result in injury, damage to the product, and sur-
rounding property.  

Intended uses are as follows:
Fountains/decorative aerators:  To provide aeration 
and a decorative display to ponds, lakes, and similar 
bodies of water.  Fountains and decorative aerators are 
provided with additional guarding to prevent acciden-
tal contact while operating.

Installation, adjustment, maintenance, and removal of 
this equipment should be limited to experienced main-
tenance persons or trained professionals.  If you are 
not sure how to install or operate any Kasco products 
call your local distributor, contact an electrician, or 
contact Kasco customer service at www.kascomarine.
com for further assistance. 

Installation requirements:

Read and understand all instructions and safety 

• 

warnings prior to installation and use.
Equipment must be installed as required by the 

• 

instructions.
Do not use this equipment outside of its intended 

• 

purpose, or if site conditions would pose a danger-
ous installation.  

Содержание 8400EJ

Страница 1: ...ukset 2 Tekniset tiedot 3 K ytt virtavaatimukset 3 Pikaliitinasetus 3 Johtojen ja tiivisteiden koko 5 Mukana tulee 5 Kokoamisohjeet 6 EVX mallin koot 8 Mallin JF suutinvaihtoehdot 8 3 vaihek ynnistys...

Страница 2: ...vioittua Viittaa 3 vaihek ynnistykseen Kiinteiss johdoissa on oltava paikallisten ja maan asennuss d sten mukainen keino kytke ne irti jotta laite ei voi k ynnisty vahingossa Piid p tev lt s hk asent...

Страница 3: ...k ytt varten Niit sa suorittaa vain koulutuksen saanut henkil Tekniset tiedot Malli J nnite Virta Lukitun roottorin virta 3 1EVX 208 240 12 5 220V 60 220V 8400EJ 208 240 9 5 220V 40 220V 3 1EJ 208 240...

Страница 4: ...n johdot ja liitokset Hartsin tulee ulottua noin 3 mm johdon kuoren p lle Huom Jos levit t liikaa hartsia ylij m saattaa joutua naarasliittimen sis n jolloin liittimet eiv t p se sulkeutumaan kunnolla...

Страница 5: ...empi kellukkeen tuki 3 Pikaliitos kirkkaalla hartsilla Huomaa johdon kuorta peitt v m r KUUDES VAIHE Liu uta tiiviste ja mutteri kuoreen ja kirist mutteri Epoksin ei tarvitse antaa kuivua ennen kokoam...

Страница 6: ...a 2 54 cm n galvanoitua putkea k ysien painoksi valinnainen D 7 16 11 mm hylsy ja r ikk 1 E 7 16 11 mm r ikk 1 F 9 16 14 mm hylsy ja r ikk 1 F 9 16 14 mm r ikk tai jakoavain 1 G Ruuvitaltta 1 Kokoamis...

Страница 7: ...ja kirist kaikki 3 8 lukkomutterit 9 16 14 mm hylsyll ja r ik ll NELJ S VAIHE K nn kokoonpano ymp ri ja aseta alemmat kelluketuet osa B3 pulttien p lle pulttien kuuluisi ulottua kokoonpanon l pi Asenn...

Страница 8: ...uuvaamalla se pumpun sis kartioon Kirist suutin alas saakka Kun asennat Redwood suutinta varmista ett Y osa osa D4 on asennettu suuttimeen asianmukaisesti Paina suutin kartio osan p lle sit t ytyy mah...

Страница 9: ...a suuttimessa kartion sis ll merkint S k ytet n 3 8 x 2 5 pulttia VAIN 3 1EJF 3 3EHJF 5 3EHJF Malli HV Korkeus Leveys 3 1 3 3 3 4 6 m 3 0 m 5 3 5 5 8 m 3 0 m Linden suuttimessa laipan sis ll merkint L...

Страница 10: ...vedess kuormitettuna J nnite Virta L1 L2 ____________ L1_______________ L1 L3 ____________ L2_______________ L2 L3 ____________ L3_______________ Virran ei tule vaihdella yli 5 t ydell kuormalla 3 va...

Страница 11: ...ja tai siimaa on kietoutunut moottorin akselin ymp rille Vaikka Kasco suihkul hteet kuuluvat markkinoiden tukkiutumattomimpiin ei ole mahdollista est kaikkien aineiden p sy laitteeseen niin kauan kuin...

Страница 12: ...olmen vuoden v lein moottori saattaa kest kauemmin ja s st kalliit korjauskulut L mp isemmill alueilla miss laite on k yt ss suurimman osan vuotta tiivisteet kannattaa vaihtaa s nn llisemmin kuin kylm...

Страница 13: ...Irrota laite verkkovirrasta Tarkista onko potkuri tai siipiratas lohkeillut tai vaurioitunut mist syyst se ei toimi asianmukaisesti Lue kokoonpanon asennusohjeet Vaihda potkuri tai siipipy r jos se on...

Страница 14: ...14 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 U S A Puh 00 1 715 262 4488 Faksi 00 1 715 262 4487 www kascomarine com sales kascomarine com 884152...

Страница 15: ...g3 Utility requirements pg3 Quick Disconnect Installation pg3 Wire Sizing Gland Sizing pg5 Parts Included pg6 Assembly Instructions pg6 EVX Pattern Size Chart pg8 J Nozzle Options pg8 3 Phase Startup...

Страница 16: ...ire a startup test after wiring to ensure proper rotation of the impeller If the impeller is rotating in the opposite direction the unit will not perform properly and internal damage to the unit may o...

Страница 17: ...ould only be per formed by a trained person Unit Specs Model Voltage range Operating amps lock rotor amps 3 1EVX 208 240 12 5 220V 60 220V 8400EJ 208 240 9 5 220V 40 220V 3 1EJ 208 240 13 2 220V 60 22...

Страница 18: ...of of the 2 part epoxy Then apply resin into the housing enough to cover the wires and contacts The resin should be about 3mm onto the cord jacket Note Adding too much resin may cause excess to be fo...

Страница 19: ...e gland nut securely No drying time is needed for the epoxy before full assembly STEP SEVEN Once the two subassemblies have been completed they can be joined together Plug pin assembly into the socket...

Страница 20: ...anized pipe for weighting ropes optional D 7 16 11mm Socket Wrench 1 E 7 16 11mm Wrench 1 F 9 16 14mm Socket Wrench 1 F 9 16 14mm Wrench or adjustable crescent wrench 1 G Flat head screw driver 1 Asse...

Страница 21: ...ttom Screen Clips Part B13 over the bolts as shown The power cord can be slid under the bottom screen where two float sections come together before the Lock Nuts are replaced Replace the three inside...

Страница 22: ...snugly into the molded socket Install the Nozzle by threading it into the inner cone of the pump Make sure to tighten the Nozzle all the way down To install the Redwood nozzle make sure the Y Insert...

Страница 23: ...e Sequoia nozzle marked S on the inside of the cone uses the 3 8 x 2 5 bolt 3 1EJF 3 3E H JF 5 3E H JF ONLY Model HP Height Width 3 1 3 3 3 4 6 m 3 0 m 5 3 5 5 8 m 3 0 m The Linden nozzle marked L ins...

Страница 24: ...__ L2 L3 ____________ L3_______________ Current unbalance should not exceed 5 at full load Installation Instructions STEP ONE Use the ropes to position the Unit in the desired loca tion in the pond la...

Страница 25: ...materials can be very damaging to the equipment under continued operation and must be removed as soon as possible ALWAYS DISCONNECT POWER TO THE UNIT BEFORE ATTEMPTING TO REMOVE CLOGS WINTER STORAGE...

Страница 26: ...of more expensive repairs In warmer climates where the equipment runs most or all of the year it is a good idea to replace seals more regularly than you would need to in colder climates where the unit...

Страница 27: ...from electrical power Check the propeller Impeller for any chipping or damage that would cause the unit to not operate properly Refer to installation instructions for assembly Replace propeller impel...

Страница 28: ...14 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 U S A Phone 00 1 715 262 4488 Fax 00 1 715 262 4487 www kascomarine com sales kascomarine com 884152...

Отзывы: