THREE-PHASE STARTUP PROCEDURE

3-phase 380V

2.3EHA

3.3EHA

Full load amps

2.6

4.1

Required motor starting/overload protection is not provided with this motor equipment.  The installer must 

supply a controller (control panel) with approved motor control and overload protection that matches motor 

input Full load amperes. (See table below.) Overload protection must be selected or adjusted in accordance 

with motor controller instructions.
Controller/control panel must also include Ground fault/leakage current protection. Installer must include 

Ground fault/leakage current protection such as a GFI, RCD, RCBB, RCBO according to local and national 

codes.   

Control panels must be installed by a qualified electrician. 

If unit is connected to a circuit protected by a fuse, use a time-delay fuse with this pump. 

You must verify motor rotation before installing the unit in the water. 

3-phase Kasco units will run in a 

clockwise rotation when looking down at the propeller. Keep clear of the propeller while verifying rotation. 

Air will be blowing out (up) of the pump chamber when rotating in the correct direction.

Electrician: 

1. 

Verify all screw terminal connections are tightened to specified torque setting prior to energizing the 

panel. 

2.  Verify the electrical service (voltage and phase) matches the control panel and fountain nameplate 

ratings. 

3.  Verify all switches, circuit breakers, and motor starters are in the OFF position
4.  Connect electrical service to the control panel.
5.  Connect the fountain power cord to the panel as shown in the electrical schematic. 
6.  Adjust motor overload protection according to motor full load amperage and motor controller 

instructions. 

7.  Pump rotation: The pump rotation is clockwise when looking down at the propeller. Apply power to the 

control panel. Turn on motor starter. 

8.  Momentarily turn on the fountain. Do not run the fountain for more than a few seconds on shore. If 

the rotation is not correct, disconnect and lock out power from the control panel. Swap any two of the 

fountain power cord wires in the panel. This will cause the motor to reverse direction. Reapply power to 

the panel and verify the rotation is clockwise. 

9. 

Once rotation is verified, with the power disconnected and locked out again, continue with installation of 

the fountain on page 6.

Record the following data while the unit is operating in the water under load:

L1-L2 

  Volts 

 

 L1 

  Amps

L1-L3 

  Volts 

 

 L2 

  Amps

L2-L3 

  Volts 

 L3 

  Amps

Current unbalance should not exceed 5% at full load.

Содержание 8400EA

Страница 1: ...UAL 1 800 Deere Rd Prescott WI 54021 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884160 Document version 2022 1 0 LARGE AERATOR 8...

Страница 2: ...Unit Specifications 2 Parts Included 3 Assembly Instructions 4 Optional Bottom Screen Assembly 5 Installation Instructions 6 Three Phase Startup Procedure 7 Maintenance Recommendations 8 Troubleshoot...

Страница 3: ...as directed by local and national codes Stay clear of all moving parts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water...

Страница 4: ...16 X 9 5 hex head screw 6 840159 C 3 8 lock nut 6 462214 D Top float bracket 3 840157 E 3 8 x 1 bolt 3 566250 F 3 8 lock washer 3 566230 G Bottom float bracket 3 840158 Optional Bottom Screen Assembly...

Страница 5: ...MANUAL 4 ASSEMBLY INSTRUCTIONS 4 G C 5 6 Float up Float down A E F 1 Flip float over to position bottom float brackets Flip float upright to secure to unit mounting ring Arrange the three float secti...

Страница 6: ...NUAL 5 OPTIONAL BOTTOM SCREEN ASSEMBLY 4 L 1 2 Optional wrap mesh around bottom screen and secure with zip ties Position bottom screen clip L so that flanges are on either side of a vertical bar on th...

Страница 7: ...ope Secondary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are too short or loose between unit and anchors Moor...

Страница 8: ...all screw terminal connections are tightened to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel and fountain namepla...

Страница 9: ...inspect and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equi...

Страница 10: ...nd will not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from...

Страница 11: ...ce the warranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any up...

Страница 12: ...for repairs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total...

Страница 13: ...n Was this unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment s...

Отзывы: