9

MAINTENANCE RECOMMENDATIONS

Proper Installation 

Proper installation of Kasco equipment will include a power source with ground fault protection. Ground 

fault protection devices can also alert you to electrical leaks in the equipment. It is extremely important 

to test the device upon installation and every month thereafter to ensure proper operation. In the case 

of consistent trips of the ground fault device, disconnect the equipment and remove it from the water. 

Inspect the power cord for damage and contact your distributor or Kasco Marine (1.715.262.4488, sales@

kascomarine.com) for further instructions.

ALWAYS DISCONNECT POWER BEFORE PERFORMING MAINTENANCE. 

Observation  

Observe equipment in operation on a regular basis (daily, if possible). If you observe a change in 

performance, disconnect the equipment from the power source and inspect for any material clogging 

the system or wrapped around the motor shaft. To avoid damage to the equipment, it is important to 

remove clogs as soon as possible. ALWAYS DISCONNECT POWER TO THE UNIT BEFORE ATTEMPTING TO 

REMOVE CLOGS.  

Cleaning 

Buildup of algae, calcium, barnacles, or other matter on the motor housing creates insulation and blocks 

heat transfer, so to prevent overheating, it is important to clean the unit. In warmer regions or in other 

areas prone to buildup such as this, inspect and clean the equipment regularly. In all regions, inspect and 

clean the equipment at least once a year. It is easiest to clean the unit immediately after removing it from 

the water, when the equipment is still wet. If you use a power washer, avoid hitting the mechanical seal 

area directly.  

Unit Storage 

Store the equipment with the cage down if it is going to be out of the water for long periods of time, such 

as during off-season storage. Seals on units that sit upright on a shelf for extended periods of time are 

more likely to dry out. Storing upside down or sideways will ensure oil is reaching the seals and help to 

prevent drying. 

Sacrificial Anode 

All Kasco units include a sacrificial anode installed on the shaft to protect against corrosion and 

electrolysis. Replace the anode if it is reduced to half the original size or if it is white in color. Corrosion 

from electrolysis most commonly occurs in saltwater or brackish water, but it is important to check the 

anode in all installations at least every two to three months.  

Seal And Oil Replacement 

This is a sealed motor assembly. Like brake pads on a car, seals wear out over time. Replace the seals and 

change the oil after three years to increase the motor’s longevity and to avoid more expensive repairs.  

Other Repairs 

Seal replacement and all other repair services should be performed at Kasco or a Kasco-trained 

authorized repair center. Please contact your Kasco distributor or representative to find your nearest 

service center.  

Please keep the original box for maintenance shipping.

Содержание 3.1EVFX

Страница 1: ...AL 1 MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884159 Document version 2022 1 0 EVFX DECORATIVE AERATOR 3 1EVFX 3 3EHVFX 800 Deere Rd Prescott WI 54021 sales kascomarine com kascomarine com ...

Страница 2: ...ons 9 Troubleshooting Tips 10 Warranty 11 Other Repairs 12 Repair Contact Form 13 UNIT SPECIFICATIONS OVERVIEW Model HP Voltage Phase Hz Amperage Locked Rotor Amps Suggested Pond Size m Min Depth of Operation 3 1EVFX 3 230 1 50 12 6 59 7 8 000 61cm 3 3EHVFX 3 380 3 50 5 23 8 000 61cm Cord Length 10m 30m 60m 90m 3 1EVFX 1 5mm 2 5mm 6mm 6mm 3 3EHVFX 2 5mm 2 5mm 2 5mm 2 5mm WIRE SIZE ...

Страница 3: ...des Stay clear of all moving parts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water especially cold water NEVER lift or drag the unit by the power cord Always use the ropes or mount to remove it from the water Do not use waders in deep water or in areas with drop offs drastic slopes or soft bottom material Do not use ...

Страница 4: ...105 E L bracket large VFX 3 284170 F 1 4 lock washer 6 840537 G 1 4 20 x 1 hex head screw 6 451130 H VFX unit assembly 1 I Bottom screen large aerator 1 990162 J Bottom screen clip large aerator 3 223240 K 3 8 16 x 1 2 serrated hex head screw 3 820092 L 3 4 mesh screen not pictured 1 990170 M Cable tie not pictured 8 415038 N Dielectric grease not pictured 1 341300 A B C D E G F H I J K ...

Страница 5: ...LARGE EVFX AERATOR MANUAL 4 ASSEMBLY INSTRUCTIONS Dedicated power cord channel H F G E 1 2 ...

Страница 6: ...LARGE EVFX AERATOR MANUAL 5 ASSEMBLY INSTRUCTIONS CONT A B C Allow movement J K 3 4 Repeat 5 ...

Страница 7: ...INSTRUCTIONS CONT Dedicated power cord channel J 6 7 8 9 Use cable ties to secure close mesh screen and then to secure it to the metal bottom screen 10 Tighten all 3 screws to secure float screen Vertical bar in between clip flanges 11 12 ...

Страница 8: ... rope Secondary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least 3 feet from the float for every foot of water depth Mooring lines are too short or loose between unit and anchors ...

Страница 9: ... are tightened to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel and fountain nameplate ratings 3 Verify all switches circuit breakers and motor starters are in the OFF position 4 Connect electrical service to the control panel 5 Connect the fountain power cord to the panel 6 Adjust motor overload protection accord...

Страница 10: ...nspect and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is still wet If you use a power washer avoid hitting the mechanical seal area directly Unit Storage Store the equipment with the cage down if it is going to be out of the water for long periods o...

Страница 11: ...nd will not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from power source to prevent motor damage Remove the equipment from the water and inspect for debris or damage Remove the debris and clean the equipment If there is no debris in the unit and it will not st...

Страница 12: ...ce the warranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information or a repair form or call to locate your nearest authorized repair center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your ...

Страница 13: ...for repairs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will res...

Страница 14: ...n Was this unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the...

Отзывы: