2400 – 4400 VFX DECORATIVE AERATOR
MANUAL
884170 / 2021.1.1
8
C-25 TIMER CONTROL INSTRUCTIONS
Portable Timer with Ground Fault Interrupter
IMPORTANT
This portable timer is designed for CONTROLLING the connected equipment only� Unplug timer before servicing the unit or the
equipment it controls� For maximum protection against electrical shock hazard, perform test procedure on GFCI at least once a month�
Mount at least 5 ft� from open water�
GFCI TEST PROCEDURE
The GFCI should be checked every month to make sure that it is operating properly� Just follow the simple instructions below� It is
recommended to maintain a maintenance diary of your monthly safety check�
1� Push TEST button, RESET button should pop out from inner surface� This should result in power being OFF at the outlet protected
by the GFCI Verify by plugging a test lamp into the outlet� Be sure the timer is in the ON position�
2� If the GFCI tests okay, restore power by pushing the RESET button back in� THE RESET BUTTON MUST BE PUSHED FIRMLY
AND FULLY INTO PLACE UNTIL IT LOCKS AND REMAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED�
DANGER:
IF RESET BUTTON DOES NOT POP OUT, IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT, OR
IF THE GFCI FAILS TO RESET PROPERLY, DO NOT USE TIMER! CONTACT A QUALIFIED SERVICE TECHNICIAN!
Failure to use the C-25 with Kasco Fountains will void the warranty and cause the Fountain to not be listed to UL and CSA standards
via ETL�
UNDER NO CIRCUMSTANCES SHOULD ANYONE ENTER THE WATER
WHEN A UNIT IS IN OPERATION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator/fountain ON & OFF with the TIMER� Kasco lights will turn ON with the PHOTO EYE and OFF
with TIMER� C-25 Control Box is to be used with Kasco Approved Lights ONLY!
• See Control panel label for instructions to set the timer
• Plug aerator/fountain cord into the RIGHT hand outlet (labeled UNIT)�
• Plug transformer light cord into LEFT hand outlet (labeled LIGHT)�
Back to Contents