background image

2400 - 4400 VFX FOUNTAIN MANUAL

2

SAFETY FIRST

UNIT SPECIFICATIONS 

OVERVIEW

Model

HP

Voltage / Phase / Hz Amperage

Locked Rotor 

Amps

Suggested Pond 

Size (m²)

Min� Depth 

of Operation 

2400EVFX

1/2

230 / 1 / 50

2.2

5.3

1,300

38cm

3400EVFX

3/4

230 / 1 / 50

3.5

12.8

2,000

45cm

4400EVFX

1

230 / 1 / 50

5.9

19.6

3,000

49cm

Cord Length

10m

30m

60m

90m

2400EVX

1.5mm

²

1.5mm

²

2.mm

²

2.mm

²

3400EVX

1.5mm

²

1.5mm

²

2.5mm

²

2.mm

²

4400EVX

1.5mm

²

1.5mm

²

2.5mm

²

4mm

²

WIRE SIZE

Moving Machinery

WARNINGS:

Shock Hazard

•  NEVER enter the water with the electrical equipment connected and/or in operation. 
•  All electrical equipment must be Ground fault/leakage current protected. Use of a Ground fault 

protective device (GFI, RCD, RCBB, or RCBO type device) is required as directed by local and national 
codes.

•  Stay clear of all moving parts.  
•  NEVER run the unit out of water. This will damage the equipment and pose a danger to the operator. 
•  Use extreme caution around water, especially cold water. 
•  NEVER lift or drag the unit by the power cord. Always use the ropes or mount to remove it from the 

water. 

• 

Do not use waders in deep water or in areas with drop-offs, drastic slopes, or soft bottom material. 

•  Do not use boats that tip easily for unit installation (such as canoes). 
•  Follow all boating safety rules and regulations, including wearing a Personal Flotation Device.
•  The unit is supplied with an internal grounding conductor. To reduce the risk of electrical shock, be 

certain that the unit is plugged in/connected to a circuit with ground fault protection. 

• 

Means for disconnection must be incorporated in the fixed wiring, in accordance with local and national 

wiring rules. 

• 

Consult a qualified electrician for electrical installation.

Back to Contents

Содержание 2400EVFX

Страница 1: ...L 1 MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884158 Document version 2022 1 0 EVFX DECORATIVE AERATOR 2400EVFX 3400EVFX 4400EVFX 800 Deere Rd Prescott WI 54021 sale...

Страница 2: ...Parts Included 3 Installation Instructions 5 Maintenance Recommendations 6 Troubleshooting Tips 7 Warranty 8 Other Repairs 9 Repair Contact Form 10 7 16 socket and ratchet 7 16 wrench 11 32 wrench for...

Страница 3: ...codes Stay clear of all moving parts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water especially cold water NEVER lift...

Страница 4: ...screw 4 251210 C 1 4 split washers 7 840537 D 1 4 3 4 OD Flat Washer 10 251300 E 1 4 20 x 1 3 4 Hex Head Bolt 3 475630 F Bottom Screen Section 3 361540 G 1 4 20 Nut 3 840536 H 8 nut 6 771034 I 8 flat...

Страница 5: ...2400 4400 VFX FOUNTAIN MANUAL 4 ASSEMBLY INSTRUCTIONS B C D I J I H Align power cord with this notch G C D D E F 1 2 3 4 5 6 Back to Contents...

Страница 6: ...ndary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least...

Страница 7: ...and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is...

Страница 8: ...not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from power so...

Страница 9: ...arranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated in...

Страница 10: ...irs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total is unde...

Страница 11: ...is unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for...

Отзывы: