background image

17 

 

Replacement Parts 

U

nit Size

 

H

 (PartNo)

 

D (PartNo) 

2hp 

8400VX 

284102 

2hp 3-phase 

2.3VX 

284103 

5hp 

5.1VX 

284105 

5hp 3-phase 

5.3VX 

284105 

Содержание 2.3HVFX

Страница 1: ...1 Manual Number 884172 Owners Manual VFX Series Aerators 8400VFX 5 1VFX 2 3VFX 5 3VFX 2 3HVFX 5 3HVFX Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 kascomarine com Rev 5 2020 ...

Страница 2: ...or use with a GFCI receptacle Control panels MUST be installed by a qualified electrician Ground Fault Circuit Interrupters GFCIs should be tested upon each installation and every month thereafter to ensure proper operation Single phase aerators are supplied with an internal grounding conductor and or a grounding type attachment plug To reduce the risk of electrical shock be certain the aerator is...

Страница 3: ...barrier that will make the unit inaccessible to persons in the water A complete list of control panels can be found in the Accessories section of kascomarine com Additional Notes During flotation operation water is pulled from 360 around and directly below the unit Keep these areas clear of debris as much as possible to decrease frequency of screen cleaning Tools and Supplies Needed 3 Anchors or s...

Страница 4: ...4 Unit Size H PartNo D PartNo 2hp 8400VFX 284102 2hp 3 phase 2 3VFX 284103 5hp 5 1VFX 284105 5hp 3 phase 5 3VFX 284105 Parts Included ...

Страница 5: ... wrench Repeat for all three legs on the unit assembly Step 2 Place the float D over the unit assembly so that it rests on the L brackets Ensure the three channels on the inside of the float line up with the threaded hole in the L brackets and the dedicated power cord channel on the underside of the float is near the cord connection on the unit assembly Dedicated power cord channel ...

Страница 6: ...on C to the ledge on the top of the float using the 3 8 16 x 3 hex head screw A and 3 8 lock washer B through the hole in the L bracket using the 9 16 socket wrench Repeat for all three upper screen sections Socket extension may be required ...

Страница 7: ...e the mesh screen L and wrap into a cone shape by overlapping both vertical edges by approximately 1 inch and aligning top and bottom edges of mesh as shown Secure mesh vertical seam at the top bottom and middle using 3 cable ties M Step 6 Insert the metal bottom screen I inside the mesh cone with approximately 2 inches of mesh overhanging the top ring of the screen Attach mesh to the top ring of ...

Страница 8: ...f the float allowing the unit power cord to exit between them in the dedicated channel Dedicated power cord channel Step 7 Flip mesh and screen assembly over and use remaining cable ties to secure mesh to small bottom diameter of the bottom screen Clip off excess cable ties once tightened and mesh is secured ...

Страница 9: ... is between the two flanges on each clip as shown Tighten all three serrated hex head screws to secure the screen to the bottom of the float being sure not to pinch the power cord 9 16 socket or combination wrench required Tighten all 3 screws to secure float screen Vertical bar in between clip flanges ...

Страница 10: ...significantly a small weight may need to be suspended at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized pipe works well The weight should be light enough so the aerator can rise as the water level rises This weight can also help hide the anchoring ropes by sinking them further below the surface After VFX unit is installed in the water connect t...

Страница 11: ...ow Electrician 1 Verify all screw terminal connections are tightened to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel and aerator nameplates ratings Refer to the control panel instructions and schematics for installation details 3 Verify all switches circuit breakers and motor starters are in the OFF position 4 Co...

Страница 12: ...iod of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEANING Aerators should be removed from the water at least once per year at the end of the season in cold climates to clean the exterior of the system especially the stainless steel motor housing can that dissipates heat into the water Any algae ca...

Страница 13: ...R CONSEQUENTIAL DAMAGES Warranty is void if The aerator is not maintained properly according to the Maintenance Recommendations supplied in this Owner s Manual The aerator is returned for repair without the power cord The unit control panel or power cord are altered in any way from original shipment Cuts in the power cord are not covered under warranty The aerator is damaged by unauthorized tamper...

Страница 14: ...Authorized Repair Center or to Kasco at Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Attn Repairs Non Warranty Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new If your aerator requires repair and is no longer covered under warranty please contact Kasco Marine or your local distributor for available options Please ship according to the instruct...

Страница 15: ... but not spinning and can be started by spinning the prop with a stick the Starting capacitor needs to be replaced by an Authorized Repair Center My Aerator turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will ...

Страница 16: ... is placed It is caused by either induced current in the ground wire or a base voltage difference due to soil pH levels To resolve the problem contact an electrician and install a local grounding stake This may eliminate the induced current and any base voltage differences This problem can also be caused by a bad breaker or receptacle or having unbalanced incoming voltage lines ...

Страница 17: ...17 Replacement Parts Unit Size H PartNo D PartNo 2hp 8400VX 284102 2hp 3 phase 2 3VX 284103 5hp 5 1VX 284105 5hp 3 phase 5 3VX 284105 ...

Страница 18: ...18 ...

Страница 19: ... unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule out site issue Note Contact Information Should be that of the person or company to contact for repair Company First Name Last Name Address City State Zip code Phone Alternate Phone Email Address Prefer...

Отзывы: