Kasco Aeration 3400JF Скачать руководство пользователя страница 18

18

Troubleshooting Tips

Below are some helpful troubleshooting tips.  If a 
problem occurs, please double check the assembly and 
installation instructions as well as the instructions for 
the proper control panel.  More troubleshooting tips 
can be found at www.kascomarine.com

“My Fountain trips the ground fault interrupter in the 
C-25, C-85, or C-95.”

 

This is the most common symptom of several 

possible problems.  To correctly diagnose the problem,  
you will need to collect more information.  A Ground 
Fault Interrupter (GFI) breaker that trips can in- 
dicate an electrical service problem, water contamina-
tion in the unit and/or cord, bad breaker, control  
box problems, motor problems, etc.  Try to fi nd out the 
answers to these questions before you contact  
Kasco to narrow down the problem.  

How long does it take to trip the breaker?  

• 

Does it always take the same amount of time to 

• 

trip?
How many times has it tripped?

• 

Has there been any electrical problems in the area 

• 

recently?

“My Fountain seems to run slowly.”

 

This can also be a symptom of several possible 

problems.  There could be an electrical problem where 
the unit is not getting the proper voltage.  This could 
also indicate a problem with the motor of the unit, 
which needs to be looked at by an Authorized Repair 
Center.  Check that the unit is receiving the   proper 
voltage, and, if so, contact Kasco for further steps.

“My Fountain hums, but will not start.  When I spin 
the prop with a stick, it starts up.”

 

This indicated a problem with the Starting 

Capacitor.  Each Kasco Fountain is equipped with a 
Starting Capacitor to get the unit going when it is fi rst 
plugged in.  If it is operating, but not spinning and can 
be started by spinning the prop with a stick, the Start-
ing capacitor needs to be replaced by an Authorized  
Repair Center.

“My Fountain turns itself off and back on without the 
timer and without tripping the GFI breaker.”

 

Each Kasco Fountain has a Thermal Overload 

built in that will turn the unit off when it overheats.  
Once the unit has cooled down, it will start back up.  If 

dress for correspondence regarding the warranty 
claim.

Any expedited shipping method for the return of the 
unit is at the customer’s expense.  Kasco Marine will 
return units repaired under warranty at our expense via 
ground freight within the continental United States.

Other Repairs:
Most failed equipment can be repaired at substantially 
lower costs than replacement with new.  Please ship 
according to the instructions in the previous section.  
Again, it is best to call ahead for a Return Authori-
zation Number and/or Repair Form so we know the 
repair is coming.

Kasco Marine does estimates on repairs at the request 
of the customer.  The request for estimate should be 
included in the letter that accompanies the returned 
unit and must include a daytime phone number and/or 
e-mail address.  Estimate options are as follows:

We will contact the customer with a total after the unit 
has been evaluated, but before the work is performed.
We will repair the unit only if repair costs are under a 
stated dollar amount.  Example: “Please repair if total 
is under $150.00 before shipping charges.”

All estimates that are rejected for repair will be de-
stroyed unless otherwise directed by the customer.  If 
the customer would like the unit returned, the unit will 
be restored as closely as possible to the condition in 
which it was received and shipped at the customer’s 
expense for shipping and handling charges.

Billing:

All non-warranty repairs will be returned to the cus-
tomer prepaid with Visa or Mastercard or shipped 
C.O.D. with C.O.D. charges unless otherwise directed.  
Kasco Marine will call for credit card information 
upon completion of the estimate.

All other warranty and repair inquiries should be di-
rected to Kasco Marine, Inc. at 715-262-4488 or 
[email protected]

Содержание 3400JF

Страница 1: ...ntrol Panel Installation pg11 C 25 Timer Control Instructions pg12 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic and 3 Phase Control Panel Timer pg15 Maintenance Recommendations pg16 Warra...

Страница 2: ...not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied...

Страница 3: ...O around the unit and from below the unit The water is pulled upward and thrust through the flotation collar into the air Your Kasco Marine Fountain is ready for immediate use after installation The m...

Страница 4: ...C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 9 16 Socket and Ratchet 9 16 Wrench 3400...

Страница 5: ...end Tighten until snug and repeat with remaining clip STEP EIGHT Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it i...

Страница 6: ...ain relief on the cord If a Strain Relief is present on the cord you may disregard the Nylon Tie On cords with a Quick Disconnect the discon nect should be tightened properly to avoid leaking If insta...

Страница 7: ...then thread into the retaining clip float retain float retaining clip ing clip Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws Set of 5 Interchangeable Nozzles 5...

Страница 8: ...e cure mesh vertical seam at the top bottom and middle STEP FIVE See Mesh Screen Attachment section before con necting the bottom screen to the float Turn secured assembly upside down so the top of th...

Страница 9: ...2 25 bolt To install simply drop the bolt through the nozzle and thread into the top of the cone on the fountain Cypress Display The Cypress nozzle marked C1 on fin makes use of the collar marked C2...

Страница 10: ...e the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weigh...

Страница 11: ...d power conductors to prevent excessive voltage drop Consult with your electrician to properly size power feed conductors Use copper conductors only Aerator power cord connection Your aerator pump wil...

Страница 12: ...Be sure the timer is in the ON position 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT should be st...

Страница 13: ...ER OPERATION INSTRUCTIONS C 25 Control Box will turn the aerator fountain ON OFF with the TIMER Kasco lights will turn ON with the PHOTO EYE and OFF with TIMER C 25 Control Box is to be used with Kasc...

Страница 14: ...14 C85 non metallic Wiring Diagram...

Страница 15: ...re pe riod that the aerator is to be turned ON i e fifteen minutes for each tripper on the 24 Hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANU...

Страница 16: ...all installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or c...

Страница 17: ...r local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void th...

Страница 18: ...off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down...

Страница 19: ...ed of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the...

Страница 20: ...R 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990281 O RING 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 342050 IMPELLER 3400J 1 13 334125...

Страница 21: ...21 4400J Replacement Parts 4400J Replacement Parts...

Страница 22: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or contr...

Страница 23: ...23...

Страница 24: ...rds Model Ex 3400JF _______________________________ Serial Ex 8001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registrat...

Отзывы: