b.

 

If the lock has not been enrolled with any other gateway, lock 
sounds a short beep after 50sec indicating unenroll 
unsuccessfully. Unenroll operation is unnecessary.  

 

After restore factory default, the enroll status of Z-Wave is still 

effective.                                                                                                          

 
 
 
 
 
 
 

Z-wave Generic Information

 

 

Generic Device Class =  
GENERIC_TYPE_ENTRY_CONTROL; 
 
Specific Device Class = 
SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK; 
 
FLIRS setting = 
APPLICATION_FREQ_LISTENING_MODE_1000ms; 
 
Device is a security enabled Z-wave production, implements Z-Wave 
Application Security Layer in accordance with Z-wave protocol. The 
functionality and support command class is difference when included 
as secure or no-secure node.  
 
Device supports Anti-theft protect function in accordance with Z-
wave Anti-theft Command Class V2. Supported command class is 
only Anti-theft CC when anti-theft protection enabled as Z-wave 
protocol.  
 
 
 
 

Содержание Z-WAVE DIGITAL LOCK

Страница 1: ...LS 8015 ZW MM BG Manual Operation Guide...

Страница 2: ...Restore Factory Default a Disconnect 1pcs battery b Press and hold the reset button c While holding the reset button reconnect the battery d Until the lock beeps release the reset button e Press digi...

Страница 3: ...y to change the default Programming Code User code 6 digits User code is the normal code for day to day operations Z Wave Every unlocking need be through Z wave Controller Index No 2 digits For each u...

Страница 4: ...ming code 4 new programming code new programming code 2 How to add one user code Function Code 1 programming code 1 user code user code 3 How to delete one user code with index No Function Code 2 prog...

Страница 5: ...lock it by press star key on the keypad manually 9 How to enroll unenroll lock to Z wave network Enroll z Put the Z wave controller into enroll mode z Input programming code 0 lock is into enroll mode...

Страница 6: ...ific Device Class SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK FLIRS setting APPLICATION_FREQ_LISTENING_MODE_1000ms Device is a security enabled Z wave production implements Z Wave Application Security Layer...

Страница 7: ...ACTURER_SPECIFIC VERSION SECURITY APPLICATION_STATUS ALARM ASSOCIATION BASIC BATTERY CONFIGURATION DOOR_LOCK DOOR_LOCK_LOGGING NODE_NAMING SCHEDULE_ENTRY_LOCK TIME_PARAMETERS USER_CODE Z Wave Command...

Страница 8: ...or Door Lock Configuration Command Auto relock timeout fix in eight 8 seconds Device treats constant Unsecure setting of Door Lock Operation as Unsecure with timeout while device auto relock mode is...

Отзывы: