11
1.3.1
Break-off Switch
This switch is used for to stop the machine while the blade pressure
gets smaller than adjusted ones. The main causes of decrease in
pressure are; dulling, cracking or breaking of blade. Operating the
machine under these conditions endanger the operator.
1.3.2
Cover Switch
This switch provides to shut down the machine while the bow
cover is open. Running the machine may cause wounding and
serious gashes. Machine gives aural warning while the cover is
open.
1.3.3
Down Limit Switch
This switch is used to adjust the bow’s nadir to goes down. Down
limit switch is a factory setting. Please do not tinker with the down
limit switch.
1.3.4
Emergency Stop Button
Emergency stop button, places on the operator control panel-
near the main switch, is red button and you can see it easily. In
emergency cases, press to this button to stop the machine.
Machine does not run while the button is pressed. To rerun the
machine, please turn left and release the button.