EN 98
The following is a list of potentially occurring problems (P) and the possible causes.
Fresh water system
(P) N
O WATER COMES OUT OF THE TAPS
.
Leave the tap in the bathroom and kitchen open for a few seconds to allow air to escape, which may have
become trapped in the water lines.
→
The fresh water tank is empty.
→
The fresh water pump is not switched on. (The symbol on the control panel is off.)
→
The filter of the fresh water pump is clogged.
→
The drain valves are open.
→
The boiler is empty.
→
The fuse for the fresh water pump (F7) has blown. (The cause has to be determined.*)
(P) T
HE WATER DOES NOT DRAIN FROM THE KITCHEN SINK
,
WASH BASIN OR SHOWER
.
→
The waste water tank is full.
→
The trap is blocked.
(P) W
ATER RUNS FROM UNDERNEATH THE VEHICLE
.
→
The fresh water tank is too full. Wait one minute until the excess water has drained.
→
The drain valve of the fresh water tank is open.
→
The waste water tank is full.
→
The drain valve of the waste water tank is open.
→
The drain valve of the boiler is open.
Electrical system
(P) O
NE OR SEVERAL ELECTRICAL APPLIANCES ARE NOT WORKING
.
→
The appliances are not in the “ON” position.
→
Circuit breaker B1 or B2 interrupts the current flow and has to be deactivated.
→
The power supply on the control panel is not activated.
→
The living room battery B2 is discharged. (See “Charging the living room battery B2”.)
→
The 230 V power supply is not established. (See “Establishing the 230 V power supply”.)
→
The RCD was triggered. (The cause has to be determined.*)
→
The fuse for for the corresponding appliance has blown. (The cause has to be determined.*)
(P) T
HE INTERIOR LIGHTING IS NOT WORKING
.
→
The power supply on the control panel is not activated. (The symbol on the control panel does not
light up.)
→
The light unit is switched off or defective.*
→
The fuse for the interior lighting (F5 or F6) has blown. (The cause has to be determined.*)
(P) T
HE EXTERIOR LIGHTING IS NOT WORKING
.
→
The power supply on the control panel is not activated. (The symbol on the control panel does not
light up.)
→
The light unit is defective.*
→
The fuse for the exterior lighting (F8) has blown. (The cause has to be determined.*)
(P) T
HE
230 V
SOCKET IS NOT WORKING
.
→
The 230 V power supply is not established. (See “Establishing the 230 V power supply”.)
→
The RCD was triggered. (The cause has to be determined.*)
Содержание DEXTER 540
Страница 1: ...DEXTER 540 BEDIENUNGSANLEITUNG OPERATING MANUAL ...
Страница 3: ...DE 3 Allgemeines ...
Страница 10: ...DE 11 Verantwortung des Halters ...
Страница 13: ...DE 15 Sicherheit und Brandschutz ...
Страница 16: ...DE 19 Beförderung von Personen ...
Страница 19: ...DE 23 Frischwasser anlage ...
Страница 27: ...DE 33 Gasanlage ...
Страница 32: ...DE 39 Elektrische Anlage ...
Страница 40: ...DE 49 Heizung ...
Страница 44: ...DE 55 WC Anlage ...
Страница 51: ...DE 63 Küche ...
Страница 55: ...DE 69 Fenster und Dach hauben ...
Страница 61: ...DE 77 Wohnen ...
Страница 69: ...DE 87 Stilllegung über den Winter ...
Страница 72: ...DE 91 Reinigung und Pflege ...
Страница 76: ...DE 97 Störungssuche ...
Страница 81: ...DE 103 Wartung und Wartungsintervalle ...
Страница 86: ...EN 3 General information ...
Страница 93: ...EN 11 Owner s responsibility ...
Страница 96: ...EN 15 Safety and fire protection ...
Страница 99: ...EN 19 Transporting passengers ...
Страница 102: ...EN 23 Fresh water system ...
Страница 110: ...EN 33 Gas system ...
Страница 115: ...EN 39 Electrical system ...
Страница 123: ...EN 49 Heating ...
Страница 127: ...EN 55 Toilet system ...
Страница 134: ...EN 63 Kitchen ...
Страница 138: ...EN 69 Windows and roof lights ...
Страница 144: ...EN 77 Living ...
Страница 152: ...EN 87 Laying up for winter ...
Страница 155: ...EN 91 Cleaning and maintenance ...
Страница 159: ...EN 97 Troubleshooting ...
Страница 164: ...EN 103 Maintenance and maintenance intervals ...