1
CAUTION
RISK
OF
ELECTRIC
SHOCK
DO
NOT
OPEN
SAFETY INSTRUCTIONS
Describes precautions that should
be observed to prevent damage to
the apparatus.
CAUTION:
The symbol is used to indicate that
some hazardous live terminals are
involved with in this apparatus,
even under the normal operating
conditions.
The symbol is used in the service
documentation to indicate that
specific component shall be only
replaced by the component spec-
ified in that documentation for
safety reasons.
Protective Ground Terminal
AC mains (Alternating Current)
Hazardous Live Terminal
ON
:
OFF
:
Denotes the apparatus turns on.
Denotes the apparatus turns off,
because of using the single pole
switch, be sure to unplug the AC
power to prevent any electric shock
before you proceed you service.
WARNING:
Describes precautions that should
be observed to prevent the danger
of injury or death to the user.
Disposing of this product should not
be placed in municipal waste and
should be separate collection.
WARNING
Ensure the source voltage matches the
voltage of the power supply before turning
ON the apparatus.
Unplug this apparatus during lightning
storms or when unused for long periods
of time.
Power supply
The external wiring connected to the out-
put hazardous live terminals requires
installation by an instructed person, or
the use of ready-made leads or cords.
There are maybe some are as with high
voltages inside, to reduce the risk of el-
ectricshock, do not remove any cover if
the power supply is connected,
Do not Remove any Cover
External Connection
The cover should be removed by the qual-
ified personnel only.
No user serviceable parts inside.
To prevent a fire, make sure to use fuses
with specified standard (current ,voltage,
type). Do not use a different fuse or short
circuit the fuse holder.
Before replacing the fuse, turn OFF the
apparatus and disconnected the power
source.
Fuse
Make sure to connect the protective
grounding to prevent any electric shock
before turning ON the apparatus.
Never cut off the internal or external pro-
tective grounding wire or disconnect the
wiring of protective grounding terminal.
Protective Grounding
8
29. THE MIC/LINE INPUT CONNECTOR.
These are the channels from Channel1 to Channel3. You can connect balanced, low impedance
microphones to the XLR socket. On the 1/4" phone jack you can connect either a microphone
or a line level instrument. You shall never connect an unbalanced microphone lt the XLR socket
if you do not want to damage both the Microphone and the Mixer.
TECHNICAL SPECIFICATION
OUTPUT POWER CAPACITY
RMS: 60W x 4
AC: 110-120V 50/60Hz
AC: 220-240V 50/60Hz
FREQUENCY RESPONSE
50Hz~18KHz (
±
3dB)
MIC : -50dB
AUX : -18dB
INPUT SENSITIVITY
BASS:
±
10dB (100Hz)
TREBLE:
±
10dB (10KHz)
<0.5%
MIC
≥
65dB
AUX
≥
75dB
MIC LEVEL CONTROL
AUX LEVEL CONTROL
TONE CONTROL (BASS, TREBLE)
AC SWITCH
PHONE CONTROL
MONITOR CONTROL
EACH CHANNEL HAS THE INPUT LEVEL CONTROL
4
Ω
, 8
Ω
50V,70V, 100V
YES
YES
YES
YES
420X342X133mm
TONE CONTROLS
OUTPUT IMPECANCE
LINE OUTPUT
CHIME FUNCTION
VU-METER (LED)
TELPHONE PAGING LELECT FUNCTION
INPUT 1 PRIORITY
DIMENSION
SIGNNAL
/
NOISE RATIO
TOTAL HARMONIC DISTORTION
POWER SUPPLY
CONTROLS
LINE : -17dB
TEL. : -30dB