Karma PAA 460 Скачать руководство пользователя страница 2

1

CAUTION

RISK

 

OF

 

ELECTRIC

 

SHOCK

DO

 

NOT

 

OPEN

SAFETY INSTRUCTIONS

Describes precautions that should 
be observed to prevent damage to 
the apparatus.

CAUTION:

The symbol is used to indicate that 
some hazardous live terminals are
involved with in this apparatus, 
even under the normal operating 
conditions.

The symbol is used in the service
documentation to indicate that 
specific component shall be only 
replaced by the component spec-
ified in that documentation for 
safety reasons.

Protective Ground Terminal

AC mains (Alternating Current)

Hazardous Live Terminal

ON

:   

OFF

Denotes the apparatus turns on.

Denotes the apparatus turns off,
because of using the single pole
switch, be sure to unplug the  AC 
power to prevent any electric shock 
before you proceed you service.

WARNING:

Describes precautions that should 
be observed to prevent the danger 
of injury or death to the user.

Disposing of this product should not 
be placed in municipal waste and 
should be separate collection.

WARNING

Ensure  the source voltage matches the 
voltage of  the power supply before turning 
ON the apparatus.
Unplug this apparatus during lightning
storms or when unused for long periods
of time.

Power supply

The external wiring connected to the out-
put hazardous live terminals requires
installation by an instructed person, or
the use of ready-made leads or cords.

There are maybe some  are as with high
voltages inside, to reduce the risk of el-
ectricshock, do not remove any cover if 
the power supply is connected,

Do not Remove any Cover

External Connection

The cover should be removed by the qual-
ified personnel only.

No user serviceable parts inside.

To prevent a fire, make sure to use fuses
with specified standard (current ,voltage,
type). Do not use a different fuse or short
circuit the fuse holder.
Before replacing the fuse, turn OFF the
apparatus and disconnected the power
source.

Fuse

Make sure to connect the protective 
grounding to prevent any electric shock
before turning ON the apparatus.
Never cut off the internal or external pro-
tective grounding wire or disconnect the 
wiring of protective grounding terminal.

Protective Grounding

 

8

29. THE MIC/LINE INPUT CONNECTOR.

These are the channels from Channel1 to Channel3. You can connect balanced, low impedance 
microphones  to the XLR socket. On the 1/4" phone jack you can connect either a microphone 
or a line level instrument. You shall never connect an unbalanced microphone lt the XLR socket
if you do not want to damage both the Microphone and the Mixer. 

TECHNICAL SPECIFICATION

OUTPUT POWER CAPACITY

RMS: 60W x 4

AC: 110-120V 50/60Hz
AC: 220-240V 50/60Hz

FREQUENCY RESPONSE

50Hz~18KHz (

±

3dB) 

MIC :  -50dB                   

AUX :  -18dB                     

INPUT SENSITIVITY

BASS: 

±

10dB (100Hz)

TREBLE: 

±

10dB (10KHz)

<0.5%

MIC

65dB

AUX 

75dB

MIC LEVEL CONTROL
AUX LEVEL CONTROL
TONE CONTROL (BASS, TREBLE)

AC SWITCH
PHONE CONTROL
MONITOR CONTROL

EACH CHANNEL HAS THE INPUT LEVEL CONTROL

4

Ω

, 8

Ω

 

50V,70V, 100V

YES

YES

YES

YES

 420X342X133mm

TONE CONTROLS

OUTPUT IMPECANCE

LINE OUTPUT

CHIME  FUNCTION

VU-METER (LED)

TELPHONE PAGING LELECT FUNCTION

INPUT 1 PRIORITY

DIMENSION

SIGNNAL

/

NOISE RATIO

TOTAL HARMONIC DISTORTION

POWER SUPPLY

CONTROLS

LINE :  -17dB                   

TEL. :  -30dB                     