Karma 622 Скачать руководство пользователя страница 8

6

11

TROUBLESHOOTING / CORRECTIVE ACTION

PROBLEM

CORRECTIVE ACTION

PROBABLE CAUSE

1. Dispenser dispenses water
only - no concentrate (with
concentrate pump working).

2. Finished drink too strong.

3. Finished drink too weak.

4. Finished drink too cold.

5. Air bubble visible in syrup
line BIB not empty.

6.Dispenses concentrate
only.

A. Concentrate motor turned off.
B. Tubing fed through pump incorrectly.
C. Out of concentrate.
D. Pump rollers not in the locked closed position.

A. Water flow or concentrate pump speed
requires adjustment.
B. Incorrect pump tubing.

A. Water and/or concentrate pump sped adjust-
ment required.
B. Incorrect pump tubing used.

A. If the dispenser was shut off, a 25 minute
heat up time is required.

A. Syrup line has loose connection or 
is damaged.

A. Water switch in “off” position.

A. Position the switches to “ON”

position.

B. Feed tubing correctly.
C. Be sure quick connect is properly   
engaged to BIB.
D. Rotate pump rollers to the closed
position.

A. Adjust pump speeds.
B. Call factory.

A. Adjust pump speeds.
B. Call factory at 1-800-558-9565

A. Allow dispenser to heat water-wait
for resady light.
B. Insure water source is on.

A. Secure loose connection or replace.

A. Position switch to “on”.

FOR PROBLEMS OTHER THAN THE ABOVE,

CALL 1-800-558-9565 AND ASK FOR THE 

SERVICE DEPARTMENT

Содержание 622

Страница 1: ...TIONS DIMENSIONS Overall 9 W x 26 D x 28 H CONSTRUCTION All Stainless Steel Cabinetry ELECTRICAL 115 V 50 60 HZ 12amps or 208 240 V 50 60 HZ 12 amps 240V PLUMBING 1 4 Waterline Filters WATER RESERVOIR...

Страница 2: ...CE COMPONENTS WITHOUT UNPLUGGING ELECTRICAL CORD CAUTION WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A PORTABLE WATER SUPPLY SHALL BE SIZED INSTALLED AND MAINTAINED ACCORDING TO FEDERAL...

Страница 3: ...ction on the 115 V model requires a minimum 15 amp outlet for the line cord to be plugged into 3 To connect this machine to 240V cut the current plug off and replace with 240V plug or hard wire Hook b...

Страница 4: ...S SHIPPED WITH PUMP ROTORS IN THE UNLOCKED POSITION PRIOR TO PRIMING LOCK BOTH PUMP ROTORS See Figure 2 2 Open the door and load both product packs into the dispenser Assemble the fitment to each prod...

Страница 5: ...cifically describing any defect promptly after discovery KARMA reserves the right or inspect products claimed to be defective and covered by warranty either at Purchaser s location or at KARMA s princ...

Страница 6: ...Fig 7 The machine has been factory set to the ratio defined at time of ordering To change this ratio you must first slow thr awa ter flow by turning the adjustment knob clockwise This knob may be fou...

Страница 7: ...ispense handle until solution has flushed all concentrate from each syrup line 5 Rinse each syrup line with at least 1 liter of 100 F water 6 Mix a solution of US Chemical Sanitizer or equivalent equa...

Страница 8: ...ump tubing A Water and or concentrate pump sped adjust ment required B Incorrect pump tubing used A If the dispenser was shut off a 25 minute heat up time is required A Syrup line has loose connection...

Страница 9: ...7 10...

Страница 10: ...9 8...

Отзывы: