Kari 3L Скачать руководство пользователя страница 7

55 mm

1

00 mm

1

55 mm

ø

1

70 mm

ROHS 

   

THE DIMENSIONS OF KARI FLOAT SWITCH

The switching height differential is adjusted to the required level by means of the 
cable weight. Curve B shows the start- and stop-height differential of the KARI Float 
Switch in relation to the distance of the weight from the float. Curve C shows the 

corresponding differential between start and alarm levels. Example: For a type 3H 
float switch, if the distance of the weight from the bottom of the float (A) is 50 cm, 

the start/alarm height differential is about 

1

2 cm.

OPERATING  CURVES TO 

FLOAT SWITCH ADJUSTMENT

The dimensions in 

the drawings are for 
illustrative purposes 
only.

cm

cm

1

20

60

80

1

00

40

20

30

50

70

90

C

A

B

D

Switching height diff

er

ential

Distance of the weight from the float

A

B

C

Weight

A QUALITY FINNISH PRODUCT

Our quality control is based on the ISO 9001 quality management 

system. Each product is subject to a full operation test. The KARI 

Float Switch is also available in versions which fulfills the U.S. and 

Canadian national safety standards.

Содержание 3L

Страница 1: ...High level alarm Issued when the level of liquid gets too high or initiates valve discharging when for example the pump is out of order Stop Lower limit for discharging Discharging pump stops KARI Fl...

Страница 2: ...pump control high level alarm Pump control with two switching elements 3YE Discharging pump control isolated high level alarm Pump control with two switching elements 3L Charging pump control low lev...

Страница 3: ...ages 2 and 3 An IP68 junction box is also available The float switch needs a cable weight or other anchor point to operate The installation site must be selected such that the float cannot become caug...

Страница 4: ...it open Circuit closed Pump control with one switching element 3Y 1 M 2 3 4 6 250V L1 L2 L3 PE U V W 1 4 1 3 1 2 High level alarm DISCHARGING PUMP CONTROL HIGH LEVEL ALARM Alarm Start Stop Circuit ope...

Страница 5: ...Pump control with one switching element 3YE 1 M 2 3 5 4 6 250V L1 L2 L3 PE U V W 1 3 1 2 4 5 High level alarm DISCHARGING PUMP CONTROL ISOLATED HIGH LEVEL ALARM Alarm Start Stop Circuit open Circuit...

Страница 6: ...op 200 mm 1200 mm Cable length 5 m other lengths supplied to order Weight of 5 m cable 1 6 kg 1 9 kg Largest diameter 170 mm Length of float casing 155 mm Buoyancy in water 6 N Float material Polyprop...