Installation Manual Kardia Alta
/
32
Aux switches
Kardia ventilation has 5 auxiliary switches for remote control.
1.
Pressure 1 - This terminal can be used to connect a pressure
sensor; the unit switches to pressure mode when enabled.
2.
Pressure 2 - same function as 1. Pressure 1.
3.
PIR - This terminal can be used to connect an external
switch; the unit switches to standby mode when this switch
is activated.
4.
Boost - This terminal can be used to connect an external
switch; the unit switches to boost mode when this switch is
activated.
5.
Fireplace - This terminal can be used to connect an external
switch; the unit switches to supply 5 and extract 3 when this
switch is activated.
Priority
1.
Pressure 1 and 2.
2.
IR (away).
3.
Boost + Fireplace.
* For project-specific logic or customization, contact Kardia.
Содержание Alta
Страница 1: ...Installation Manual Kardia Alta...
Страница 10: ...9 Connection Roof plate connection...
Страница 18: ...17 Step 6 Lock the wheel brackets...
Страница 28: ...27 Roof Plate...
Страница 32: ...31 Electrical Wiring Diagram...
Страница 43: ...Switchboard 47 64 86 50 00 Email contact kardia no www kardia no...