Chapter 3 Operation Panel
26
Code
Parameter
Function
Explanation
Parameter Value
Factory
Setting
Pr.066
Second fault
record
d0000
Pr.067
Third
fault
record
d0000
Pr.068
Parameter
lock
/
restore
setting
d0000: parameters can be written and read
(need 5 to 10 minutes to reset)
d0000
d0001: parameters are read only
d0002-d0009: Reserved
d0010:Restore HQM when Pr.68 = 10
d0011: Reserved
d0012: Reserved
d0019:General modes (need 5-10s to
restore)
Pr.069
Baud rate
d0000—d0016
d0002
Pr.070
Contact
address
d0000—d0031
d00001
Pr.071
Exclusive
mode
d0000 HQM model
d0001 ZS model
d0002 MD model
d0003-d0004 reserved
d0009 general model
d0000
Pr.072
AVR
output
function select
d0000: disable
d0001
d0001: enable
Pr.073
Acceleration
time 1
d000.1—d99.99 s
d00.02
Pr.074
Deceleration
time 1
d00.01—d99.99 s
d00.02
Pr.075
Acceleration
time 2
d00.01—d99.99 s
d00.02
Pr.076
Deceleration
time 2
d00.01—d99.99 s
d00.02