6
If the pump basin was completely empty
(dry run), the pump basin will first have to
be completely filled.
Then, the swimmer switch S4.1 will release
the submersion pump and normal opera-
tion is warranted once more.
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
In der Anlage enthaltenes Restwasser
muss vor dem Transport entfernt werden.
When transporting in vehicles, secure the
appliance according to the guidelines from
slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
In der Anlage enthaltenes Restwasser
muss vor der Lagerung entfernt werden.
Store the appliance in a frost free area.
The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggessted by him, such as
–
replacement and wear parts
–
Accessory parts
–
Fuel
–
Detergent
Danger
Risk of accident while working on the unit.
During all tasks
Deenergize the system: Pull the mains
plug and secure the system against be-
ing switched back on.
Shut off water supply.
–
Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the
washing system.
–
Customer Service
Only KÄRCHER service engineers are
allowed to carry out work with the note
“Customer Service”.
In order to ensure a reliable operation of the
plant, we recommend that you conclude a
maintenance contract with us. Please refer
to you local KÄRCHER service depart-
ment.
Monitoring and regulating equipment
Float switch in the recycled water tank
S7 top
Recycled water tank full. Filling process is stopped.
S7 bottom
Recycled water tank is filled.
S9 top
Switching off the fresh water supply. Indicator lamp "Fresh water supply active" goes
off. Illuminated lamp "Fresh water supply was active" lights up red.
S9 bottom
Switching on the fresh water supply. Indicator lamp "Fresh water supply active" and
"Fresh water supply was active" lights up red.
S11 top
Dry run protection for wash pump not active, no error message.
S11 bottom
Dry run protection for wash pump active, error message on the washing system.
Floater switch in the pump basin
S5 top
Pump basin overfilled. Starting the disposal via the recycling water tank into the channel
S5 bottom
Pump basin is not overfilled, normal system operation.
S4.1 top
Pump basin is not sufficiently filled, normal system operation.
S4.1 bottom
no function
S4.2 top
no function
S4.2 bottom
Pump basin empty, dry run protection of immersion pump active, no filtration, no back-
wash possible. System runs on fresh water.
Technical specifications
WRP 3000 Comfort
Immersion pump
Motor output
W
1000
Voltage
V
230/1~
Power consumption
A
4,4
Flow rate at approx. 0.25 MPa (2.5 bar)
m
3
/h
asi 3
Pressure
MPa (bar)
max. 0,25 (2,5)
Entire unit
Filter capacity
m
3
/h
max. 3
Voltage
V
230/1~
Frequency
Hz
50
Width
mm
630
Depth
mm
480
Height
mm
1400
Weight
kg
55
Transport
Storing the device
Maintenance and care
Maintenance instructions
Who may perform maintenance?
Maintenance contract
17
EN
Содержание WRP 3000 Comfort
Страница 2: ...2 ...