High-pressure cleaner does not build up
the pressure or is vibrating
.
Dismantle the high-pressure nozzles,
check the high-pressure nozzles for
damage, rinse the T-Racer with clean
water then reinstall the high-pressure
nozzles.
Illustration
1 Loosen the safety clamp with a screw-
driver.
2 Remove the protective grid.
3 Remove the clip.
4 Pull out the high-pressure nozzle.
Rinse the high-pressure nozzle with
clean water, replace if necessary.
5 Insert the nozzle.
6 Reinsert the clip.
7 Mount the protective grid on the pin.
8 Push the safety clamp in until it locks.