15
Maintenance
Only qualified maintenance personnel are to
perform the following repairs.
Vacuum Motor Replacement
1.
Turn off all switches and unplug machine.
2.
Remove hardware under front of machine to
access component compartment.
3.
Remove vacuum motor cover and disconnect
motor wires.
4.
Remove the vacuum motor.
5.
Reverse process to install vacuum motor.
Vacuum Motor Carbon Brushes Replacement
3
8
[9.5mm]
Carbon
Brushes
End Cap
WARNING: The
green ground wire
must be attached for
safe operation. See
wiring diagram.
If armature commutator is grooved, extremely pitted
or not concentric, the motor will need to be replaced
or sent to a qualified service center.
Important:
These brushes wear quicker as the length shortens
due to increased heat. Spring inside brush housing
will damage motor if brushes are allowed to wear
away completely.
Periodically check the length of the carbon brushes.
Replace both carbon brushes when either is less than
3/8" (9.5mm) long.
Содержание PUZZI 50/14E
Страница 19: ...86343350 PUZZI 50 14E PARTS...
Страница 20: ...20 86343350 PUZZI 50 14E Control Panel 5 2 11 10 10 1 4 12 6 3 7 8 9 13 14 15...
Страница 22: ...22 86343350 PUZZI 50 14E Electrical 6 8 4 2 11 7 5 17 9 12 1 3 10 15 13 14 16 3 18 19...
Страница 24: ...24 86343350 PUZZI 50 14E Frame 1 2 3 4 5 6 7 8 9 10 11...
Страница 28: ...28 86343350 PUZZI 50 14E Labels 1 2 3...
Страница 32: ...32 86343350 PUZZI 50 14E Recovery 21 10 17 9 7 1 10 12 13 10 5 20 16 14 8 2 4 19 3 15 18 11 6...
Страница 34: ...34 86343350 PUZZI 50 14E Solution 7 14 24 22 1 1 1 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...
Страница 36: ...36 86343350 PUZZI 50 14E Vacuum 2 Stage 12 11 10 9 8 7 6 5 4 3 2 1 4 13...
Страница 41: ...86343350 PUZZI 50 14E 41 Serial Numbers REF NO MODEL SERIAL 1 N A...
Страница 42: ...42 86343350 PUZZI 50 14E Notes...