CAUTION

Always work with an inserted flat fold filter - 
during wet as well as dry vacuum cleaning!

Illustration 

Remove the appliance head and take 
the contents out of the container.

Turn the container, press in the steering 
roller in the openings at the base of the 
container till the end-point. 

Insert and lock the appliance head.

Clip the holder for the accessory com-
partment onto the rear side of the appli-
ance.

Illustration 

Connect accessories.

Illustration 

Plug in the mains plug.

Illustration 

Turn on the machine.

CAUTION

Work with a dry flat fold filter only.

Check the filter for damage prior to installa-
tion and replace as necessary.
Illustration 

For vacuuming dry dirt an additional fil-
ter bag can be inserted if necessary.

CAUTION

Only operate the filter cleaning without a fil-
ter bag inserted, otherwise the filter bag 
can get damaged.

– The filling level of the filter bag depends 

on the dirt that is sucked in. 

– The filter bag needs to be replaced 

more frequently while sucking in fine 
dust, sand, etc.

– Clogged filter bags can burst - therefore 

make sure to replace the filter bag in a 
timely manner!

CAUTION

Vacuum cold ashes only when using a pre-
filter.

Order no. basic design: 2.863-139.0, pre-
mium design: 2.863-161.0.

Caution:

Do not use a filter bag!
Immediately switch the appliance off if foam 
forms or liquids escape!
Immediately switch the appliance off or pull 
the power plug if foam forms or liquids es-
cape!
Do not use a filter bag!

Note: 

If the container is full, a float closes 

the suction opening, and the appliance 
works at a higher speed. Switch off the ap-
pliance immediately, and empty the con-
tainer.

For vacuuming up moisture or wetness 
pay attention to the correct floor nozzle 
setting and connect the corresponding 
accessories.

Adapt the adapter to the connection di-
ameter of the electric tool using a knife 
if necessary.

Illustration 

A

) Plug the enclosed adapter onto the 

handle of the suction hose and connect 
the electric tool with the connection.

or

B

) Use the flexible tool hose to gain 

more flexibility in your work. Connect 
this hose to the suction hose and to the 
adapter and then to the connection of 
the electric tool.

Operation

Before Startup

Start up

Dry vacuum cleaning

Information filter bag

Wet vacuum cleaning

Working with electrical power tools

9

EN

Содержание MV 5 P

Страница 1: ...59655000 09 14 MV 5 Premium MV 6 P Premium Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them English 5...

Страница 2: ...8 9 9 10 11 13 12 17 19 20 15 14 16 18 21 22 MV 6 P Premium 2...

Страница 3: ...3 4 3...

Страница 4: ...H H H2 G G 4...

Страница 5: ...your old appli ances using appropriate collection sys tems Filters and filter bags are made from envi ronment friendly materials They can therefore be disposed off through the normal household garbage...

Страница 6: ...y only be connected to al ternating current The voltage must corre spond with the type plate on the appliance Risk of electric shock Never touch the mains plug and the socket with wet hands Do not pul...

Страница 7: ...hnical data Illustration To connect an electric tool Illustration Connect the suction hose to the blower connection this will activate the blower function Illustration For cleaning the flat pleated fi...

Страница 8: ...ustration Connect the handle with the suction hose until it snaps in place Illustration To remove the handle from the suction hose press the notch using your thumb and pull off the handle Note Due to...

Страница 9: ...therefore make sure to replace the filter bag in a timely manner CAUTION Vacuum cold ashes only when using a pre filter Order no basic design 2 863 139 0 pre mium design 2 863 161 0 Caution Do not use...

Страница 10: ...the filter cleaning button 3 x while the appliance is switched on wait 4 seconds between the individual operations Note After operating the filter cleaning but ton several times check the container f...

Страница 11: ...Illustration Unlock fold out and remove the filter cartridge Illustration Remove the flat fold filter from the filter box and tab it out When necessary clean under running water only do not wipe or br...

Страница 12: ...1 50 60 Hz Output Pnom 1100 1300 W Max connection output of appli ance socket 2100 W Mains fuse slow blow 10 16 A Container capacity 30 30 l Water intake with handle 15 20 l Water intake with floor no...

Страница 13: ...2 863 148 0 MV 5 Pemium MV 6 P Pemium 5 965 500 0 24 09 14 9 084 160 0 AU MV 5 Premium 6 650 501 0 AU MV 6 P Premium...

Страница 14: ...www karcher co nz www karcher com au...

Отзывы: