18
English
Banbury
Oxon, OX16 1TB
or E-mail us
:
Subject to technical modifications!
We hereby declare that the machine de-
scribed below complies with the relevant ba-
sic safety and health requirements of the EU
Directives, both in its basic design and con-
struction as well as in the version put into cir-
culation by us. This declaration shall cease to
be valid if the machine is modified without our
prior approval.
The undersigned act on behalf and under the
power of attorney of the company manage-
ment.
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Technical specifications
Power connection
Voltage
1~50/60 Hz
230-240 V
Connected load
1,9 kW
Mains fuse (slow-blow)
(EU)
(GB)
10
13
A
A
Protective class
I
Protection class
IP X5
Water connection
Max. feed temperature
30 °C
Min. feed volume
10 I/min
Max. feed pressure
0,6 MPa
Performance data
Working pressure
11 MPa
Max. permissible pressure
13 MPa
Water flow rate
6,7 I/min
Burner performance
25 kW
Detergent flow rate
0,4 I/min
Recoil force of trigger gun
16 N
Hand-arm vibration
(ISO 5349)
1,05 m/s
2
Sound pressure level
L
pA
(EN60704-1)
75 dB(A)
Sound power level
L
WA
(2000/14/EG)
93 dB(A)
Dimensions
Length
700 mm
Width
525 mm
Height
915 mm
Weight
40 kg
Fuel
Light heating oil or Diesel
(below 6°C: winter diesel)
Fuel tank
5 l
CE declaration
Product:
High-pressure cleaner
Type:
1.185-xxx
Relevant EU Directives
2006/95/EC (to 28.12.2009)
2006/42/EC (from 29.12.2009)
2004/108/EC
2000/14/EC
Applied harmonized standards
EN 60335–1
EN 60335–2–79
EN 55014–1: 2006
EN 55014–2: 1997 + A1: 2001
EN 61000–3–2: 2006
EN 61000–3–3: 1995 + A1: 2001 + A2: 2005
EN 62233: 2008
Applied conformity evaluation method
Appendix V
Sound power level dB(A)
Measured:
91
Guaranteed:
93
CEO
Head of Approbation
Содержание K 855 HS
Страница 2: ...2...