28
English
5.906-591.0 Rev. 00 (01/14)
Subject to technical modifications!
*The max. flow rate is derived from the measurement with-
out the backflow valve installed.
No data.
When working on the device, please always use the cur-
rent circuit diagram in DISIS.
Technical Documentation
Appliance type
Appliance no.
Circuit diagram
Operating instruc-
tions
Spare parts list
K 6.200
1.446-000.0
1.446-001.0
0.089-226.0
5.964-673.0
5.965-054.0
5.972-214.0
K 7.200
1.447-000.0
1.447-001.0
0.089-226.0
5.964-673.0
5.965-054.0
5.971-607.0
K 7 Compact
1.447-002.0
1.447-003.0
1.447-004.0
0.089-226.0
5.965-162.0
5.971-607.0
Technical specifications
K 6.200
K 7.200
K 7 Compact
Electrical connection
Voltage
230
1~50
V
Hz
Connected load
2,5
3,0
3,0
kW
Protection class
IP X5
Protective class
I
Mains fuse (slow-blow)
16
A
Water connection
Max. feed pressure
0,6
MPa
Max. feed temperature
60
°C
Min. feed volume
12
I/min
Max. Suction height
1,0
m
Performance data
Working pressure
13
15
15
MPa
Max. permissible pressure
15
16
16
MPa
Water flow rate
8,8
9,2
9,2
I/min
Recoil force of trigger gun
20
22
22
N
Detergent flow rate
0 - 0,3
I/min
Dimensions and weights
Length
552
mm
Width
290
mm
Height
333
mm
Weight, ready to operate with accessories
17,0
18,7
19,2
kg
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
< 2,5
0,3
m/s
2
m/s
2
Sound pressure level L
pA
Uncertainty K
pA
77
3
dB(A)
dB(A)
Sound power level L
WA
+ Uncertainty K
WA
93
94
93
dB(A)
Torques
Circuit diagram