Maintenance table
Replacing the surface filter
1. Loosen the screw connections of
the clamping rings.
2. Remove the baffle plate.
3. Remove the filter.
4. Fit a new filter.
Note
Ensure that the filter has been in-
serted correctly.
5. Fit the baffle plate.
6. Fit the clamping rings and screw
tight.
Interval
Check
Measure
Daily
Check the pocket filter for
contamination
Clean the contaminated pocket
filter
Check the suction hose for
leaks
Replace a leaky suction hose
Collection container filling
level
Empty the full collection contain-
er
Check the surface filter for
contamination
Clean the contaminated surface
filter
Check the seal between the
drive unit and the collection
container for leaks
Clean or replace the seal
Compressed air display
Ensure an optimum compressed
air supply of 5.6 bar
Vacuum pump display at
least 90 %
Service the pump
Weekly
Check the collection contain-
er for contamination
Clean the contaminated collec-
tion container
Monthly
Check the filling level moni-
toring hose/emptying hose
for contamination
Clean the filling level monitoring
hose/emptying hose
3-6 months
Check the pump for contam-
ination
Service the pump
Annually
Filter foam
Replace