Have all checks and work on electrical
parts performed by an qualified technician.
Note
The device must be switched off immedi-
ately in the event of a malfunction. The mal-
function must be eliminated before
switching the device on again.
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Suction turbine does not start up
1. Check the socket and the power supply
fuse.
2. Check the mains cable and the mains
plug of the device.
3. Switch the device on.
Suction power decreases
1. Remove the blockages from the suction
nozzle, the suction pipe or the suction
hose.
2. Replace the filled dust bag (see chapter
3. Check that the suction head and the dirt
receptacle are correctly seated.
4. Dedust the main filter (see chapter
5. Check the seating of the filter and cor-
rect if necessary.
6. Replace the main filter (see chapter
).
Escaping dust when vacuuming
1. Check the seating of the filter and cor-
rect if necessary.
2. Dedust the main filter (see chapter
3. Replace the main filter (see chapter
).
Disposal
At the end of its service life, the device is to
be disposed of in accordance with statutory
regulations.
Warranty
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
Electrical connection
Mains voltage
V
220-
240
Phase
~
1
Power frequency
Hz
50-60
Nominal power
W
3150
Maximum power
W
3600
Protection class
IPX4
Protection class
I*
Maximum permissible
mains grid impedance
Ω
0.195+
j0.122
Dimensions and weights
Typical operating weight
kg
81
Length x width x height
mm
1020 x
680 x
1890
Filter area of main filter
m
2
2.24
Filter area of the H filter
m
2
3.5
Ambient conditions
Storage temperature
°C
-10-40
Device performance data
Container capacity
l
100
Vacuum (with pressure re-
lief valve)
kPa
25.4
Air quantity
l/s
3x 74
Suction hose connection
NW
DN70
Nominal width of the suc-
tion hose
DN40/
50/70
Determined values in acc. with EN
60335-2-69
Hand-arm vibration value m/s
2
< 2.5
Uncertainty K
m/s
2
0.2
Sound pressure level L
pA
dB(A) 79
Uncertainty K
pA
dB(A) 2