background image

16 

English 

5.906-757.0 Rev. 00 (10/15)

WARNING

Switch off the appliance and remove the plug from the 
socket.
Observe general safety information!

No special functional characteristics.

Note

Unless otherwise described, the installation takes place in 
reverse order.

ACSK Uninstall / install suction head

1 Bracket filling level sensor
2 Screws
3 Intermediate ring

Unscrew the screws.

Remove the bracket of the filling level sensor.

AH Service group

010 Safety information

020 Overview

AHFS Uninstall / install filling level sensor
AHGA Uninstall / install power switch
AHSE Uninstall / install control electronics 1
AHSF Uninstall / install control electronics 2

030 Function

040 Service activities

AHFS Uninstall / install filling level sensor

Содержание IVC 60/24-2 Tact2

Страница 1: ...English 5 906 757 0 Rev 00 10 15 1 IVC 60 24 2 Tact Service Manual...

Страница 2: ...8 070 Peculiarities others 8 AC Service group suction system 9 010 Safety information 9 020 Overview 9 030 Function 9 040 Service activities 9 ACSK Uninstall install suction head 9 ACST Uninstall ins...

Страница 3: ...English 5 906 757 0 Rev 00 10 15 3 060 Error diagnosis 18 070 Peculiarities others 18 Technical Documentation 19 Technical specifications 19 Circuit diagram 20...

Страница 4: ...arty access to this information is permitted only with the explicit permission of the company Alfred K rcher GmbH Co KG Postfach 160 71349 Winnenden Germany www kaercher com Service and maintenance ta...

Страница 5: ...red in operational or their functions bypassed Observe safety information in the chapters The type plate is located on the rear of the appliance 1 Appliance description 2 Part number 3 Year of manufac...

Страница 6: ...the appliance and remove the plug from the socket Observe general safety information No special functional characteristics Parts of the system Front view AB Service group setup 010 Safety information...

Страница 7: ...stall instrument panel 1 Screw 2 Handle Loosen screws Remove the handle 1 Screws 2 Cover filter Open the cover of the filter Unscrew the screws 1 Electric socket plug connections 2 Control electronics...

Страница 8: ...opening of the cover Remove the hood Installation information Upon reinstallation make sure that no cables are jammed 1 Screws 2 Instrument panel Unscrew the screws Tilt the instrument panel forwards...

Страница 9: ...Intermediate ring 2 Screws 3 Machine frame Unscrew the screws Remove intermediate ring Service group does not contain any maintenance and in spection points The service group does not contain any erro...

Страница 10: ...akes place in reverse order 1 Nut 2 Electric connectors Unscrew the nut Separate the electric connectors AC Service group suction system 010 Safety information 020 Overview ACTM Uninstall install Tact...

Страница 11: ...latches 2 Suction head Open lock latches Remove the suction hand ABHA Uninstalling installing cover 1 Screws 2 Control electronics 2 Unscrew the screws Remove control electronics 2 1 Screw Loosen scr...

Страница 12: ...ine 1 2 Electrical socket plug connections suction turbine 2 Separate the electric connectors Note Observe the connection diagram 1 Screws 2 Casing suction turbine 3 Suction turbine Unscrew the screws...

Страница 13: ...Pull on the lock Open the cover of the filter 1 Flat fold filter Remove flat folded filter ABHA Uninstalling installing cover 1 Screws 2 Cover Tact unit Unscrew the screws Remove cover Tact unit ACFF...

Страница 14: ...Remove tact unit 1 Screwdriver 2 Locking nose 3 Casing cover Tact unit Detach the Tact unit from the latches using a screwdriv er Remove casing cover of the Tact unit 1 Sealings 2 Guide Tact magnets 3...

Страница 15: ...electric connectors Disconnect electric screw connections Remove tact magnets Installation information Observe the connection diagram The pocket filter should be serviced or if necessary re placed aft...

Страница 16: ...Uninstall install suction head 1 Bracket filling level sensor 2 Screws 3 Intermediate ring Unscrew the screws Remove the bracket of the filling level sensor AH Service group 010 Safety information 02...

Страница 17: ...t 3 Intermediate ring Unscrew the covering nut Pull the filling level sensor out of the intermediate ring ABIT Uninstall install instrument panel 1 Electric socket plug connections 2 Screws 3 Power sw...

Страница 18: ...ip 3 Mains cable Unscrew the screws Remove strain relief Remove mains cable Note Mind correct installation of the lines ABIT Uninstall install instrument panel 1 Control electronics 1 Disconnect all e...

Страница 19: ...ews Remove control electronics 2 Note Observe the connection diagram Service group does not contain any maintenance and in spection points The service group does not contain any error diagnosis The se...

Страница 20: ...bar 25 4 254 22 0 220 Type of protection IP X4 IP X4 Protective class I I Suction hose connection C DN C ID DN 72 72 Nominal width of suction hose DN 42 52 42 52 Length x width x height mm 970 x 690 x...

Страница 21: ...English 5 906 757 0 Rev 00 10 15 21 Circuit diagram...

Страница 22: ...ndicator lamp L1 Magnet L2 Magnet M1 Suction turbine M2 Suction turbine N1 Control electronics 1 N2 Control electronics 2 S1 Power switch X1 Mains plug X2 Terminal strip X4 Plug socket contacts fillin...

Отзывы: