– 8
Technical specifications
HV 1/1 Bp
Charger
Mains voltage
V~
220-240
Frequency
Hz
1~ 50-60
Battery pack
Battery voltage
V =
18
Rated capacity (according to IEC/EN 61690)
mAh
2500
Battery run time (normal operation)
Minutes
21
Battery run time (Eco mode / power saving mode)
Minutes
35
Device
Container capacity
l
0,9
Air volume (max.)
l/s
33
Negative pressure (max.)
kPa (mbar)
4,7 (47)
Protective class
III
Suction hose connection (C-DN/C-ID)
mm
35
Length x width x height
mm
306x116x290
Typical operating weight
kg
1,8
Ambient temperature
°C
0...40
Values determined to EN 60335-2-69
Sound pressure level L
pA
dB(A)
70
Uncertainty K
pA
dB(A)
1
Hand-arm vibration value
m/s
2
< 2,5
Uncertainty K
m/s
2
1
Rated power input
W
115
18
EN