Basic Settings and Service Procedures
HDS Middle Range / HDS Premium Range
Page 82 / 127
Service Manual 04.2008
3.1.18
Pump services
Function
140 °C
LED display
Meaning
SCTR_PUMPE
Pump service display.
The value is displayed
by the LEDs, digit for
digit, whereby each LED
stands for a numerical
value from 0 to 9
according to its number.
Numerical value „0“
Value
The display is repeated
after a pause.
Example:
The pump has been
serviced 7 times since
the initial operation of the
unit.
The LEDs light up in the
following order:
- PAUSE -
.
.
.
Numerical value „1“
Numerical value „2“
Numerical value „3“
Numerical value „4“
Numerical value „5“
Numerical value „6“
Numerical value „7“
Numerical value „8“
Numerical value „9“
140 °C
+
„SET“
When the unit is switched on the pump operating time since the pump service
(SI_PUMPE) is set to „0“, the pump service counter (SCTR_PUMPE) is increased by
1 and the fault memory is deleted.