7.10 Testing the water temperature setting and the programme switch
Function
Adjustments
LED indicator
Important
55 °C
(46/38 °C)
ENCPROGTEST
With this function, the pro-
gramme switch and the
controller for the water
temperature setting can
be tested.
Upon switch-on, all 10
LEDs are on.
By operating the push-
button function of the
service switch (contin-
ue to turn to "SET" posi-
tion and release) and
turning the water tem-
perature setting to 30°C,
the test is started.
If the water temperature
setting is gradually in-
creased, the LED display
changes as shown to the
right.
30 °C
(30/30 °C)
35 °C
(34/32 °C)
40 °C
(37/34 °C)
45 °C
(40/35 °C)
50 °C
(43/36 °C)
55 °C
(46/38 °C)
60 °C
(48/40 °C)
65 °C
(50/42 °C)
70 °C
(52/44 °C)
75 °C
(55/45 °C)