background image

– 7

Do not use stop chains.

Protect the lifting device from inadvert-
ent load release.

Remove spray lance with hand spray 
gun, nozzles and other loose objects 
prior to transportation by crane.

Do not transport any articles on the ap-
pliance during the lifting process.

The appliance must only be transported 
by properly trained crane personnel.

Do not stand below the load.

Ensure that no persons are present in 
the immediate vicinity of the crane.

Do not leave the appliance on the crane 
unattended.

CAUTION

Risk of injury and damage! Note the weight 
of the appliance in case of storage.

This appliance must only be stored in inte-
rior rooms.

DANGER

Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before 
carrying out any tasks on the machine. 

You can sign with your dealer a contract for 
regular safety inspection or even sign a 
maintenance contract. Please take advice 
on this matter.

Check connection cable for damages 
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer ser-
vice person/ electrician.

Check the high pressure hose for dam-
ages (risk of bursting). 
Please arrange for the immediate ex-
change of a damaged high-pressure hose.

Check appliance (pump) for leaks.
3 drops per minute are permitted and 
can come out from the lower side of the 
appliance. Call Customer Service if 
there is heavy leakage. 

Clean the sieve in the water connection.

Take out sieve.

Clean the sieve from the outside and 
rinse it.

Insert sieve.

DANGER

Risk of injury by inadvertent startup of ap-
pliance and electrical shock.

Prior to all work on the appliance, 
switch off the appliance and pull the 
power plug.

Get the electrical components checked 
and repaired only by authorised cus-
tomer service persons.

Contact an authorised customer service 
person in case of problems not men-
tioned in this chapter or if you are in 
doubt or when you have been explicitly 
asked to do so.

Check connection cable for damages.

Check the supply voltage.

If the appliance is overheated:
Set the appliance switch to "0".
Allow machine to cool down at least for 
15 minutes. 
Set the appliance switch to "1".

Call Customer Service in case of elec-
trical defects.

Check the nozzle size, install correct 
nozzle.

Deaerate the appliance (see "Start-up")

Clean the sieve in the water connection.

Check water supply level (refer to tech-
nical data).

Clean the nozzle.

Replace the nozzle.

Contact Customer Service if needed.

Storage

Care and maintenance

Safety inspection/ maintenance 

contract

Before each use

Weekly

Clean the sieve in the water connection

Troubleshooting

Appliance is not running

Pressure does not build up in the 

appliance

9

EN

Содержание HD 5/11 Cage

Страница 1: ...HD 5 11 Cage 97617870 02 18 English 3 Espa ol 12...

Страница 2: ...2...

Страница 3: ...s situation which can lead to severe injuries or death CAUTION Pointer to a possibly dangerous situation which can lead to minor injuries ATTENTION Pointer to a possibly dangerous situation which can...

Страница 4: ...ground is recommended Unsuitable electrical extension cables can be hazardous Only use electrical extension cables outdoors which have been approved and labelled for this pur pose and have an adequat...

Страница 5: ...for the surface to be cleaned to determine the safety and health requirements The respective re quired protective measures must be taken Do not open the hood when the motor is running Let the hoses co...

Страница 6: ...pressure jet e g cleaning of facades terraces garden ing tools With optional accessories detergent can be added For stubborn soiling we recommend the use of a rotor nozzle only included in the scope o...

Страница 7: ...type BA must be used Water that was flowing through a system separator is considered non drinkable CAUTION Always connect the system separator to the water supply never directly to the appli ance For...

Страница 8: ...ill destroy the not completely water drained device Store the appliance in a frost free area Drain water Pump in conventional frost protection agents through the appliance Note Use normal glycol based...

Страница 9: ...e hose Check appliance pump for leaks 3 drops per minute are permitted and can come out from the lower side of the appliance Call Customer Service if there is heavy leakage Clean the sieve in the wate...

Страница 10: ...nd of the operating instructions you will find a selected list of spare parts that are often required For additional information about spare parts please go to the Service section at www kaercher com...

Страница 11: ...0 5 Max feed pressure MPa bar 1 10 Performance data Working pressure MPa bar 11 110 Nozzle size 036 Max operating over pressure MPa bar 16 160 Water flow rate I min 8 1 Max recoil force of trigger gu...

Страница 12: ...tuaci n propablemente peligrosa que puede provocar lesiones cor porales graves o la muerte PRECAUCI N Indicaci n sobre una situaci n que puede ser peligrosa que puede acarrear lesiones leves CUIDADO A...

Страница 13: ...versal mostrado en el manual de instrucciones y estar protegido ante chorros de agua La conexi n no debe sumergirse en agua El enchufe y el acoplamiento de un con ducto de prolongaci n tienen que ser...

Страница 14: ...a limpiar ropa o calzado No limpie los neum ticos ni las v lvulas de los neum ticos a una distancia me nor de 30 cm De lo contrario podr da ar los neum ticos o las v lvulas de los neum ticos con el ch...

Страница 15: ...on todas las normas de seguridad pertinentes Los equipos ambulantes de uso indus trial deben someterse al control de se guridad de acuerdo con las normativas locales vigentes p ej en Alemania VDE 0701...

Страница 16: ...n clase de protecci n 1 y su ficiente corte trasversal v ase Datos t cnicos y enrollar desde la parte de lantera del tambor del cable Valores de conexi n v ase la placa de ca racter sticas datos t cni...

Страница 17: ...esgo p ej gasolineras se deben respetar las re glamentaciones de seguridad correspon dientes PRECAUCI N Da os medioambientales Limpiar los mo tores solo en las zonas con el separador de aceite corresp...

Страница 18: ...dosificadora con la pis tola pulverizadora manual boquillas y otros objetos sueltos antes del trans porte con gr a Durante el proceso de elevaci n no transportar ning n objeto en el aparato El aparato...

Страница 19: ...n la po sici n 1 En caso de un defecto el ctrico consul tar al servicio de atenci n al cliente Comprobar el tama o de la boquilla montar la boquilla correcta Purgar el aparato v ase Puesta en marcha L...

Страница 20: ...ato ser n subsanadas gratuitamente dentro del periodo de garant a siempre que se de ban a defectos de material o de fabricaci n En un caso de garant a le rogamos que se dirija con el comprobante de co...

Страница 21: ...entrada m x MPa bar 1 10 Potencia y rendimiento Presi n de trabajo MPa bar 11 110 Tama o de la boquilla 036 Sobrepresi n de servicio m xima MPa bar 16 160 Caudal agua l min 8 1 Fuerza de retroceso de...

Страница 22: ......

Страница 23: ......

Страница 24: ...Alfred K rcher GmbH Co KG Alfred K rcher Str 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212 http www kaercher com dealersearch...

Отзывы: