WATER SUPPLY 

 

(Cold Water Only)

CAUTION

When connecting the water inlet to the water 
supply mains, local regulations of your water 
company must be observed. In some areas 
the unit must not be connected directly to the 
public drinking water supply. This is to ensure 
that there is no feedback of chemicals into the 
water supply. Direct connection via a receiver 
tank or backflow preventer, for example, is 
permitted.

Dirt in the feed water will damage the unit. To 
avoid this risk, we recommend fitting a water 
filter.

„

Garden hose must be at least 3/4 inch in 
diameter.

„

Flow rate of water supply must not fall 
below 3,0 GPM (HD 2.3/15 C Ed), 4,0 GPM 
(HD 3.0/20 C Ea) (gallons per minute).

„

Flow rate can be determined by running the 
water for one minute into an empty 5-gallon 
container.

„

The water supply temperature must not 
exceed 140°F/60°C.

„

Never use the pressure washer to draw in 
water contaminated with solvents, e.g. 
paint thinners, gasoline, oil, etc.

„

Always prevent debris from being drawn 
into the unit by using a clean water source.

CANADA:

WARNING

Do not spray electrical apparatus and wiring.

Do not use with flammable liquids and toxic 
chemicals

.

Injection hazard: equipment can cause 
serious injury if the spray penetrates the skin. 
do not point the gun at anyone or any part of 
the body. In case of penetration seek medical 
aid immediately.

 

This system is capable of producing 
10400 kPa /1500 PSI  (HD 2.3/15 C Ed),  

13000 kPa /2000 PSI  (HD 3.0/20 C Ea) to 
avoid rupture and injury, do not operate this 
pump with components rated less than 
10400 kPa /1500 PSI  (HD 2.3/15 C Ed),  
13000 kPa /2000 PSI  (HD 3.0/20 C Ea) 
working pressure (including but not limited to 
spray guns, hose and hose connections).

Before servicing, cleaning or removing any 
parts, shut off power and relieve pressure

.

Extension Cords

„

Use only 3-wire extention cords that have 
3-prong grounding-type plugs and 3-pole 
cord connectors that accept the plug from 
the product.

„

Up to 100 ft = 12/3 AWG; 

„

Use only extension cords that are intended 
for outdoor use. These extension cords are 
identified by the marking “Acceptable for 
use with outdoor appliances; store indoors 
while not in use.”

„

Use only extension cords having an 
electrical rating not less than the rating of 
the product.

„

Do not use damaged extension cords.

„

Examine extension cord before using and 
replace if damaged.

„

Do not abuse extension cord and do not 
yank on any cord to disconnect.

„

Keep cord away from heat and sharp 
edges.

„

Always disconnect the extension cord from 
the receptacle before disconnecting the 
product from the extension cord. 

„

If you are using an extension cord, it should 
always be completely unwound from the 
cable drum.

WARNING

To reduce the risc of electrocution, keep all 
connections dry and off the ground. Do not 
touch plug with wet hands.

SAVE THESE 

 

INSTRUCTIONS!!

Содержание HD 2.3/14 C Ed Food

Страница 1: ...www kaercher com HD 2 3 15 C Ed HD 3 0 20 C Ea HD 2 3 14 C Ed Food 5 961 971 0 03 07...

Страница 2: ...2 English 4 Fran ais 13 Espa ol 22...

Страница 3: ...3...

Страница 4: ...ger Gun Safety Lock PREVENTS the trigger from accidentally being engaged This safety feature DOES NOT lock trigger in the ON position Do not use extension cord with this unit GROUNDING INSTRUCTIONS Th...

Страница 5: ...se of penetration seek medical aid immediately This system is capable of producing 10400 kPa 1500 PSI HD 2 3 15 C Ed 13000 kPa 2000 PSI HD 3 0 20 C Ea to avoid rupture and injury do not operate this p...

Страница 6: ...ad these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Clean ers No 5 951 949 Use of the cleaner Use this appliance exclusively for cle...

Страница 7: ...er Mount the accessories Mount nozzle on the spray lance see markings on the top of the setting ring Fit the spray lance to the hand held spray gun For appliances without hose reel Undo push handle cl...

Страница 8: ...f necessary allow unit to continue running for 10 sec onds and then switch off Repeat this pro cedure several times Switch off the unit and screw the nozzle back on Operating the unit Danger Observe t...

Страница 9: ...ugh for one minute Interrupting the operation Release lever of the handgun the unit switches off Retract lever again and the unit switches on again Switching the unit off Set unit switch to 0 and pull...

Страница 10: ...ng hours Change the oil For oil quantity and type see Technical Specifications Undo the fastening screw remove the hood remove the oil tank cover tilt unit Drain oil into a suitable container Fill slo...

Страница 11: ...or check it for leaks remove obstruction Seek the help of Customer Service if nec essary Spare parts You will find a list of spare parts at the end of these operating instructions Warranty The warrant...

Страница 12: ...ner 20 C ft m 1 6 0 5 1 6 0 5 1 6 0 5 Supply pressure max psi MPa 145 1 145 1 145 1 Performance data Operating pressure psi MPa 1500 10 3 2000 13 8 1400 9 7 Max operating overpressure safety valve psi...

Страница 13: ......