Troubleshooting and basic settings
Unit does not reach required pressure
Checking flow rate
Setting operating pressure
Fitting the shut-off valve
Check flow rate
– Mount the water inlet hose.
– Mount the shut-off valve at the high-pressure
outlet.
– Connect the high-pressure hose with hand-
gun (no nozzle) to the shut-off valve.
– With the handgun open, start up the unit.
– Use the shut-off valve to set operating pressu-
re (see technical data).
– Using a suitable container, time and measure
the water flow volume (e.g., liters per minute).
If there is too little water, there may be an
external water loss (visible water leakage) or
an internal water loss (concealed water leaka-
ge), e.g., pressure valves, suction valves,
overflow valve leaking.