OPERATING INSTRUCTIONS

Engine with fixed throttle:

Move the engine stop switch to the ON

position.

For more details see engine manual.

Step 9

Pull the starter handle.

If  the  engine  fails  to  start  after  3  pulls,

squeeze  the  trigger  gun  to  release

pressure, and repeat step.

After the engine warms up enough to run

smoothly, move choke rod to OPEN position

and throttle to FAST position.

Important!

Do not run the engine with a high or low oil

level as this can cause engine damage.
If you have further questions regarding the

engine,  please  refer  to  the  engine’s

operating manual included with the unit.

Step 1

Check oil level on engine before starting the

unit. Oil level should always be between the

“FULL” and “ADD” marks on the dipstick.

Be sure the machine is level when checking

the oil level. (Refer to the engine’s operating

manual for seasonal grades.).

We recommend that the oil be changed after

the first 2 hours of use, then once every 25

hours.

Step 2

Fill gas tank with unleaded gasoline.

Do not use leaded gasoline.

Step 3

Connect the high pressure hose to the unit’s

high pressure outlet.

Step 4

Connect garden hose to unit’s water inlet.

Step 5

Connect  garden  hose  to  the  cold  water

source and turn water on completely.

Do not use hot water.

Step 6

Trigger the gun to eliminate trapped air, wait

for a steady flow of water to emerge from

the spray nozzle.

Step 7

Pull the choke rod to the CLOSED position

Starting a Warm Engine:

If the engine has run out of fuel, pull the choke

rod to the CLOSED position after refueling.

If the engine has not run out of fuel, leave

the choke rod in the OPEN position.

Step 8

Engine with manual throttle:

Slide the throttle lever away from the SLOW

position, about 1/3 of the way toward the

FAST position.

MAINTENANCE INTERVALS FOR PUMP

We recommend that the oil be changed after

the first 100 hours of use, then once every

500 hours.

Recommended oil for pump

Use multi-grade 4-stroke motor oil that meets

or exceeds the requirement for API service

classification SH, SJ, or equivalent.

Use oul SAE-class 15W-40.

Oil Change for pump

Drain the pump oil when the pump is warm.

Warm oil drains quickly and completely.

1. Place a suitable container below the pump

to catch the used oil.

2. Remove the oil fill cap, the oil drain plug

and washer.

3. Allow the used oil to drain completely, then

reinstall the drain plug and washer. Tighten

the drain plug securely.

Please dispose of used oil in a manner that

is  compatible  with  the  environment.  We

suggest  you  take  used  oil  in  a  sealed

container to your local recycling center. Do

not throw it in a trash or pour it on the ground

or down a drain.

4. With the pump in a level position, fill in

0.350 liters (11.84 Fl.oz) of recommended

oil. Do not overfill.

Notice:

Running the pump with a low oil level can

cause pump damage.

5. Reinstall the oil fill cap securely.

Содержание G 2800 OH

Страница 1: ...G 2800 OH 9 139 171 03 05 English 2 Espa ol 14 Fran ais 26...

Страница 2: ...rage 9 Cleaning Tips 10 11 Optional Cleaning Accessories 11 Troubleshooting 12 13 Specifications Max Pressure 2800 PSI Water volume 2 6 GPM Detergent suction 0 15 0 20 GPM Engine 6 0 HP Honda GC 190 P...

Страница 3: ...pressure hose 5 Gas tank 6 Spray wand 7 Dipstick 8 Water inlet with garden hose connector 9 High pressure outlet 10 Detergent filter 11 Detergent suction tube 12 Spark plug 13 Hose Reel optional Moun...

Страница 4: ...sure quickly Be thoroughly fa miliar with the controls Stay alert watch what you are doing Do not operate the product when fatigued or under the influence of alcohol or drugs Do not stand on unstable...

Страница 5: ...loaded collar of the wand back to insert your choice of quick connect nozzle Step 7 Attach the high pressure hose to the spray gun Step 8 Prior to initial startup cut off tip of oil reservior cap DANG...

Страница 6: ...ow of water to emerge from the spray nozzle Step 7 Pull the choke rod to the CLOSED position Starting a Warm Engine If the engine has run out of fuel pull the choke rod to the CLOSED position after re...

Страница 7: ...step 6 The color coded quick connect nozzles provide a wide array of spray widths from 0 to 65 and are easily accessible when placed in the convenient rubber nozzle hol der which is provided on the ba...

Страница 8: ...thinners gasoline oils Tri sodium phosphate products Ammonia products Acid based products These chemicals will harm the unit and will damage the surface being cleaned For best results see Cleaning Tip...

Страница 9: ...he throttle lever to theSLOW position to shut down engine Allow the engine to idle for a few seconds then move the throttle lever to the STOP position Engine with fixed throttle Move the engine stop s...

Страница 10: ...keeping the spray nozzle approximately 6 inches from the cleaning surface Caution Do not use Dirtblaster Spray Nozzle on siding as it may cause damage Cement Patios Brick and Stone with or without det...

Страница 11: ...ure with or without detergent Pre rinse furniture and surrounding area with fresh water If using K rcher All Pur pose and Vehicle Wash Canada Pressure Wash place detergent suction tube directly into c...

Страница 12: ...ries high and low Not enough inlet water supply Turn water on full force Check garden hose for kinks leaks or blockage Pump is sucking air Check that hoses and fittings are air tight Turn off machine...

Страница 13: ...stomer support for help WARRANTY USA See enclosed warranty card WARRANTY CDN K rcher Canada Inc warrants to the origi nal owner that this product shall be free from defects in material and workmanship...

Отзывы: