English
7
Faults during charging
Battery pack not charging, display
is on
Defective charger.
1. Replace the charger.
Battery pack not charging, display
is off
Battery pack is completely discharged
or defective.
1. Wait and see if the display shows
the remaining charging time after a
while.
If the display remains off then the
battery pack is defective.
2. Replace the battery pack.
Battery pack not charging, display
shows the temperature symbol
The battery pack temperature is too
low/high.
1. Put the battery pack in a moderate
temperature environment and wait
until the battery pack temperature
returns to the normal range, see the
"Technical data" chapter.
The charging process begins auto-
matically.
Battery pack does not charge, dis-
play is off or indicates charging
state - red indicator light on the
charger is off
The charger is defective.
1. Please contact the service partner.
Technical data
Subject to technical modifications.
Fast Charger
18/60
Fast Charger
36/60
Universal
Charger 18-
36/60
Electrical connection
Battery pack nominal
voltage
V
18
36
18/36
Charging power max.
A
6
6
6
Battery pack type
Li-ION
Li-ION
Li-ION
Battery platform
Battery Power /
Battery Power+
Battery Power /
Battery Power+
Battery Power /
Battery Power+
Mains voltage
V
1
20
1
20
1
20
Frequency
Hz
50 - 60
50 - 60
50 - 60
Current consumption
A
1,5 @ 110 V
2,9 @ 110 V
2,9 @ 110 V
Protection class
II
II
II
Dimensions and weights
Weight (without battery
pack)
g
854
933
935
Permissible temperature
range during charging
process
°C
4 - 40
4 - 40
4 - 40
Length x width x height mm
192 x 137 x 81 192 x 137 x 81 192 x 137 x 81