background image

System Start 

 

 

 

 

1.Set the 4th Value of IP with switch. 

* Refer to "

Setting IP Address

" for more details.

 

 

2. Connect with KRNET.   

* Refer to "

System Connecting

" for more details.

 

 

 

 

3. Connect the Audio Output Terminal.   

 

4. Connect the Power Cable, and press the 
Switch for Power supply.   

 

 

 

5. Check if POWER ON LED is lit up normally.   

 

6. Check if IP address is normally displayed 
    as you set. 

 

Содержание KUT-NA 130

Страница 1: ...Network Amplifier KUT NA 35 65 130 250 500 Operating Manual...

Страница 2: ...ns 1 Features 1 Operating elements of Front panel 2 Operating elements of Rear panel 3 System Connections 4 Setting IP Address 6 System Start 7 System Menu 8 Block Diagram 9 Specifications 10 Accessor...

Страница 3: ...Features This device is a TCP IP Network based Class D Amplifier for Public Address System developed by applying the AoIP Technology which is the cutting edge digital technology It is a Network Termin...

Страница 4: ...It provides 8 Audio Outputs Speaker Output of each Channel is composed of COM 8Ohm 75V 100V Protective function is built in against the Overcurrent Overvoltage and Overheat of the Amplifier...

Страница 5: ...Channel It turns off when the trouble is solved 3 DISPLAY It is a window to show Main Information Please refer to the Menu Explanation for more detailed explanations 4 ROTATING SWITCH It is a Rotatin...

Страница 6: ...th KRNET Division Content Giga Optic Used for composition of Tree Network Ring Port1 Used for composition of Ring Network Ring Port2 4 This is an Input Terminal of AC Power Source 5 This is a Terminal...

Страница 7: ...ess 5 If you divide the 4th value of required IP Address by 16 the Quotient is the first Switch Value and the Remainer is the second Switch Value Setting Example Set the IP with 192 168 100 3 Quotient...

Страница 8: ...Rotary Value 0 1 2 3 4 5 6 7 8 9 A B C D E F Decimal Number 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Страница 9: ...for more details 2 Connect with KRNET Refer to System Connecting for more details 3 Connect the Audio Output Terminal 4 Connect the Power Cable and press the Switch for Power supply 5 Check if POWER O...

Страница 10: ...Address of the Equipment Firmware VER Shows the Firmware Version running at the Equipment Connection Host Shows the Connection Status with Host None No Connection is made with Host PHY Physical Connec...

Страница 11: ...Block Diagram...

Страница 12: ...5W 130W 250W 500W Frequency Response 60 20 3 S N More than 90 T H D Less than 0 1 1 Power AC 220V DC 24V Power Consumption Model KUT NA35 KUT NA65 KUT NA130 KUT NA250 KUT NA500 Consumption 500W 750W 7...

Страница 13: ...failure due to abuse or operation outside the specified ratings Warranty applies to original purchaser only Warranty gives you specific rights which vary from state to state For more Information rega...