background image

6

• Do not remove or deface warning labels on the laser level.

• Do not disassemble the laser level. 

• Do not drop the laser.

• Do not use solvents to clean the laser.

• Do not use in temperatures below -20°C or above 50°C

  (-4°F / 122°F)

• Do not operate the laser in explosive atmospheres such as   

  flammable liquids, gases or dust. Sparks from the tool can  

  cause ignition.

• When not in use remove the batteries, engage the 

  pendulum lock and place the laser in the carrying case.

• Make sure the pendulum lock mechanism is engaged  

  before transporting the laser.

   

      NOTE 

If the laser level is not in use for a prolonged 
period of time, remove the batteries from the 
battery compartment to prevent leakage or/
and corrosion damage.
If the pendulum lock mechanism is not 
engaged before transportation, internal 
mechanical damage may occur.

Содержание Prolaser Electrota 8991

Страница 1: ...PROLASER ELECTROTA Self leveling Rotary Laser Level Model No 8991 Rechargeable batteries included 165 50m Up to 300m 980 with detector 4 x C type included User Manual...

Страница 2: ...o achieve accurate results and reduce valuable work time APPLICATIONS The Prolaser Electrota 8991 has been designed for use in most areas of construction for example Laying foundations Wall and fence...

Страница 3: ...c Mode 9 Inclined Plane 10 Manual Mode 11 Vertical Setup 12 Plumb Down 13 Scan Function 13 Manual Rotation 14 Automatic Drift System 14 Laser Detector 15 Using the Laser Detector 15 Using the Remote C...

Страница 4: ...d battery Charger AC DC Converter Plumb Down Plumb Up point Rugged design with protective handles Freestanding or fits onto standard tripod 5 8 thread Remote control included Laser Detector included S...

Страница 5: ...e the laser level Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope as this will increase the level of eye injury WARNING This product contains lead in s...

Страница 6: ...s or dust Sparks from the tool can cause ignition When not in use remove the batteries engage the pendulum lock and place the laser in the carrying case Make sure the pendulum lock mechanism is engage...

Страница 7: ...7 Main body 1 Laser Diode 2 Plumb Up Beam window 3 Control Panel 4 Carrying Handle 5 Charger socket OVERVIEW...

Страница 8: ...rol Panel 1 Rotation left 2 Rotation right 3 Manual Auto in manual mode the self leveling is disabled 4 Power On Off 5 Automatic drift system 6 Rotation Speed Control 7 Direction Scanning 8 Y AXIS 9 X...

Страница 9: ...tal plane 2 Press the On Off button The power indicator will light up and the laser beam will blink If the instrument is set up outside the 5 limit themanualindicatorwillblinkandrotationwillnotbegin 3...

Страница 10: ...link If the instrument is set up outside the 5 limit the manual indicator will blink and rotation will not begin 3 The Rotary Laser is ready to work when the laser beam no longer flashes The instrumen...

Страница 11: ...e Rotary Laser see page 16 This option is very useful for trench work or when laying concrete 9 To turn the Rotary Laser off press the On Off button Manual Mode If the Manual Auto button is pressed an...

Страница 12: ...wer button to turn the Rotary Laser on The power indicator will light up and the laser beam will start to blink 3 Verify that the Rotary Laser is in Automatic mode the manual indicator must be unlit 4...

Страница 13: ...the Plumb Down beam with the tripod legs as in step 5 7 Repeat step 6 until the Plumb Down beam is sufficiently accurate for your purposes 8 If you wish to transfer a point to the ceiling use the Plum...

Страница 14: ...0 rpm or in scan mode you can manually rotate the beam using Rotation left and Rotation right keys Automatic drift system Use this function to prevent misaligning the laser level while in automatic mo...

Страница 15: ...ing which mode was selected 3 Select the sound or mute mode The sound symbol appears on the display when you select the sound option No symbol indicates that you are in mute mode 4 Turn the detection...

Страница 16: ...infra red control and the remote control sensor on the control panel The effective range of the remote control is 20m The Remote Signal Indicator flashes when a signal has been sent 1 Remote Signal I...

Страница 17: ...argeable battery pack inside or outside of the laser level The Rotary Laser can be operated while recharging It takes approximately seven hours to fully charge the batteries Brand new or unused rechar...

Страница 18: ...ace them with two AAA batteries 4 Replace the cover External Power Supply The Prolaser Electrota 8991 can use an external DC power source This will minimize the risk of battery failure during operatio...

Страница 19: ...oap and water solution Do not use harsh chemicals cleaning solvents or strong detergents Keep the laser aperture of the Rotary Laser clean by wiping it with a lint free cloth moistened with isopropyl...

Страница 20: ...ximately 50m 165ft from a wall or measuring staff 2 Position the Rotary Laser so that the X axis is pointing in the direction of the measuring staff or wall 3 Turn on the Rotary Laser 4 Mark the heigh...

Страница 21: ...wall staff 3 Position the laser on vertical leveling side 4 Turn on the Rotary Laser with the Plumb up Plumb down projecting onto walls Check and mark points hA and hB on both walls 5 Reposition the l...

Страница 22: ...t 60 120 300 600 rpm Rotational Coverage scanning function 0 stationary point 10 45 90 180 360 Setting slope 5 dual axis Effective Working Temperature 4 F 122 F 20 C 50 C Remote Control Distance Appro...

Страница 23: ...he warranty does not cover products that are used improperly altered or repaired without Kapro Tool s approval In the event of a problem with the laser level please return the product to the place of...

Страница 24: ...24 Rev 1 0 2019 Kapro Industries Ltd...