background image

18

Stud Layout Setting

You can define a set measurement to use when doing 

equidistant layouts. 

For example, if you need to layout studs at 24cm apart, 
you can define this distance from the Settings menu F3. 

Once you have defined the distance:

1. Select the Dynamic Measuring mode.
2. Position the laser at the beginning of your layout line.

3. From the starting point, move the laser along a straight line. When you  
  get close to the defined distance, the laser displays arrows to help  
  you find the exact point and beeps when you are aligned. 

Laser Pointer Mode

You can activate the laser pointer from the Settings 
menu F4. 
Press   or   to turn the laser on and off.

Maintenance

•  Clean the aperture lens and the

  Kapro Laser Distance Measurer body using a clean soft cloth only. Do  
  not use solvents.

•  If the laser measurer is exposed to water, dry it before storing.
•  Remove the battery if the laser measurer will be unused for a long  

  period of time.

Содержание KAPROMETER K4 370

Страница 1: ...KAPROMETER K4 LASER DISTANCE MEASURER Model No 370 User Manual 2AA 230 70m...

Страница 2: ...owner of one of our Innovative range of state of the art tools These tools incorporate new laser technology enabling the professional user and the serious D I Y enthusiast to quickly achieve accurate...

Страница 3: ...ctivation 10 Distance Measuring 10 Dynamic Continuous Measuring 12 Area Measurement 13 Volume Measurement 14 Indirect Measurement 15 Measuring Reference Point 15 Laser Pointer 15 Backlight 15 Tripod M...

Страница 4: ...klit LCD display Measures area and volume Indirect measuring using Pythagorean theorem Choice of 3 reference points Advanced memory function Impact resistant rubber Tripod ready 1 4 thread Accuracy 1...

Страница 5: ...measurer Do not look into a laser beam using magnifying optical equipment such as binoculars or telescope as this will increase the level of eye injury Do not take the unit apart Do not drop the laser...

Страница 6: ...ries Battery status is indicated by an icon on the initial screen If the icon is displayed continuously there are approx 1 000 measurements left If the icon is flashing the battery is low The battery...

Страница 7: ...D Area Volume Measuring Functions E Backlight Timer F Subtract G Power Switch Clear H Indirect Measurement I Measuring Reference Point Settings Menu J Tripod Thread K Battery Cover L Belt Holder M Las...

Страница 8: ...as Difference of two Pythagoras 3 Measuring Function Area Volume 4 Measuring Reference Point 5 Add and Subtract 6 Maximum Display 7 Minimum Display 8 Stud Layout Indicator 9 Main screen display a Meas...

Страница 9: ...t Speed 0 5 seconds Laser Class II 650 nm 1mW Battery AA batteries x2 Battery Life Up to 10 000 measurements Dimensions 120mm x 55 mm x 32mm Operating Temperature 5 C 23 F to 40 C 104 F Storage Temper...

Страница 10: ...arget and press MEAS The measured distance appears on the main screen To change the units of measurement see Settings Standby Screen Measurement Done Adding Measure ments To calculate the sum of two m...

Страница 11: ...easurements appears on the screen Dynamic Continuous Measuring To activate continuous measuring 1 Press and hold MEAS to change from normal to Dynamic Measuring The laser beam is activated and begins...

Страница 12: ...een 3 and 15 seconds 2 Set the laser in the position you want to measure from and press to start the timer A beep is sounded when the measurement has been taken Area Measurement To measure an area 1 P...

Страница 13: ...nt To measure the volume of an area 1 Press twice to select volume measurement and activate laser beam 2 Follow the instructions on the screen to measure width length and height Volume measurement app...

Страница 14: ...2 to measure height indirectly To take an indirect measurement 1 Press to select the type of indirect measurement and activate laser beam 2 Follow the instructions on the main screen to measure the le...

Страница 15: ...efault the reference point is set at the rear To change the reference point press Each reference point changes in the following sequence front middle rear Backlight To activate and de activate backlig...

Страница 16: ...eter K4 s memory holds up to 20 measurements You can display the measurements on the screen from the Settings menu F1 Scroll through the measurements using the and buttons The type of measurement disp...

Страница 17: ...17 Indicator for unit of measurement Meter Feet Inch 0 0 1 32 inch R Length m ft in 0 0 1 32 in R Area m ft ft ft ft Sf R Volume m ft ft ft ft m...

Страница 18: ...ve the laser along a straight line When you get close to the defined distance the laser displays arrows to help you find the exact point and beeps when you are aligned Laser Pointer Mode You can activ...

Страница 19: ...esult of the area or volume is out of the display range Divide the measurement span into sections and add the results Err04 Indirect measurement calculation error Verify that the measurements were tak...

Страница 20: ...warranty card Kapro Industries Ltd Kapro Tools Inc Kadarim 20117 Israel 195 Enterprise Drive Tel 972 4 698 6204 Lake Mills Wl 53551 USA Fax 972 4 698 7228 Tel 1 800 4 LEVELS E mail quality kapro com W...