16
Applying Power
After wiring is completed, apply power to the KT-315. Connect the battery leads to the battery, and connect the AC transformer.
Then, connect power to the KT-PC4204; the battery leads followed by the AC transformer.
NOTE:
Do not connect the power until all wiring is complete.
Assigning the KT-PC4204 Module
Once wiring is completed, the module must be assigned to the system. To assign the module, perform the following:
1. Establish communication between the PC and the controller.
2. Remove the tamper switch wire (or only the wire if tamper switch is not used).
3. A serial number should be displayed in the EntraPass message desktop. Look for the type of module and the controller to
which it is connected.
4. From the EntraPass controller definition window, select the functionality of the module and enter the serial number in the
appropriate field (refer to Chapter 4, Defining Devices or your EntraPass Reference Manual for more details).
5. If the module is used in “repower” mode, assign an “Always valid” schedule to relay 1 and assign the module’s functionality
to “relay 1 to 4” in the EntraPass software.
NOTE:
Do not forget to reconnect the tamper switch (or the wire, if there is no tamper switch).
NOTE:
Ensure that Jumper J1 is set to “Combus Relay” position if used as “repower”.