kansai HAS Series Скачать руководство пользователя страница 2






Places with a lot of dust, dust, etc.

Places where acid gas, corrosive gas, etc. are floating

Places with low atmospheric pressure

Places with conductive suspended matter (carbon fiber, etc.)

atten:

When carrying, do not hang a hoist or hanging band on the handle.

In a closed room and in a case

A place where the back is close to  a wall

Places above 1000m above sea level

Places with an ambient humidity over 85% R.H.

Places other than ambient temp 0 to + 40 ° C

Near combustibles

Places that cannot be installed or used

Place with vibration

Places exposed to wind and rain outdoors

Top of fever

1.Installation

Install it in a horizontal position.
Please fix it firmly if necessary.

2.Piping

 fix the piping to the outlet

Due to the characteristics of the flexible hose, hot air leaks from the flexible hose piping to the outlet. The leaked hot air will flow
back into the multi-dryer and cause damage to the electronic devices in the operation panel. Use the enclosed glass tape to prevent
air leakage and install the flexible hose piping to the outlet

3.Power supply

Make the piping as thick and short as possible, and install it with a gentle bend.
Be sure to insulate the piping sufficiently.

Please provide a dedicated circuit. When installing an earth leakage breaker, make a decision with a
sensitivity current of about 50mA as a guide.

The sensitivity current of the earth leakage breaker is generally about 10 times the initial leakage current.

To prevent electric shock accidents, perform grounding work (class D grounding).

Ask an electrician for power connection and grounding work.
Do not use the 100V type with the same outlet power supply at the same time as other devices.
For 200V type, use the attached outlet for wiring.

Connect the 200V type power cord according to R (red), S (black), and ground (green + yellow: with ground seal).

Be sure to use a commercial power supply (50 / 60Hz) with a sinusoidal waveform for the multi-dryer.
Never use a power supply that has distorted waves containing harmonics. Also, take sufficient measures to
prevent surge voltage and noise from entering the power supply.

Atten:

Please note that wiring that is too long will cause a voltage drop.

Atten:

Be sure to shut off the power supply during wiring and inspection. Even if the power switch of the main unit is turned off,
the operation circuit of the multi-dryer is still energized, so be sure to turn off the factory power supply (primary power
supply). If you work with the power turned on, you will get an electric shock.

Atten:

If you provide an outlet for the connection, ensure sufficient capacity. Please refrain from using the outlet as much as
possible because the outlet may generate heat or break down due to poor contact due to deterioration over time, phase
loss, etc.

Atten:

A multi-dryer is a device mainly used in an industrial environment. When used in a residential environment, etc., there is a
risk of radio interference. At that time, the user of this product may have to take appropriate measures to reduce the
obstacle.

※When using a single-phase 100V power supply with a single-phase three-wire low-voltage distribution system,
the single-phase 200V power supply can be easily taken out from the distribution board. If you are using a single-phase 200V model,
please consult with an electrician, including the power supply capacity.

-1-

Содержание HAS Series

Страница 1: ...nufacturer 8 Maintenance and inspection Please hand out this manual to the final user 保存用 MANUAL 4 Intermittent operation 5 Each abnormality indication 6 Filter replacement 7 When using as a shoulder type Please be sure to read before use Thank you for purchasing the Multi Dryer 1 Installation 2 Piping 3 Power supply MULTI DRYER HAS series Warranty KANSAI ELECTRIC HEAT CORP Check the name plate to...

Страница 2: ...on and grounding work Do not use the 100V type with the same outlet power supply at the same time as other devices For 200V type use the attached outlet for wiring Connect the 200V type power cord according to R red S black and ground green yellow with ground seal Be sure to use a commercial power supply 50 60Hz with a sinusoidal waveform for the multi dryer Never use a power supply that has disto...

Страница 3: ... perform energy saving operation to restart the operation of the multi dryer Set the hot air temperature while stopped Since this set temperature is the upper limit temperature of the discharge port of the multi dryer set the temperature in consideration of the set temperature of the external sensor heat dissipation from the piping etc If there is no upper limit on the discharge port temperature s...

Страница 4: ... key once to turn the set temperature display to ON Press the hot air switch 8 times PAo is displayed in the hot air temperature section and oFF Is displayed in the set temperature section When the sensor temperature in the constant temperature bath reaches the set value the multi dryer stops operation and then starts operation again when the temperature inside the tank drops to the set arbitrary ...

Страница 5: ...the power switch again Depending on the abnormality it may be possible to recover with the stop switch Also only the overheat for detecting the temperature of the heater case will be manually restored Clogged suction port filter insufficient air volume due to excessive resistance on the discharge side or exceeding the upper limit of the discharge port temperature when using an external sensor OVER...

Страница 6: ... set for the set temp section Flashes When the external sensor temp drops below 15 the abnormal lamp red flashes flashes in the hot air temp section and Tc0 flashes in the set temp section EXTERNAL SONSOR BURNOUT EXTERNAL SONSOR MINUS DISPLAY OPTION OPTION Internal temp sensor minus display After the external sensor malfunction is improved the operation can be resumed with the stop switch Bearing ...

Страница 7: ...red inside the muffling box 5 sheets are included at the time of shipment THE WAY OF FILTER EXCHANGE Loosen the two knurled screws at the bottom of the muffling box Remove the mute box and remove the filter Take out the replacement filter stored inside the muffling box and attach it to the main body muffling box ローレットビス Filter filter for exchange When using it for carrying around tie the power cab...

Страница 8: ...nt It may cause a malfunction In order to use this machine more safely we recommend that you carry out a self inspection if the usage period exceeds 10 years voluntary inspection point insulation resistance value heater current value voluntary inspection HIGASHIOSAKA CITY OSAKA 577 8566 JAPAN manufact urer KANSAI ELECTRIC HEAT CORP 5 CHOME 4 18 TAKAIDANISHI HOT AIR GENERATOR Tightening inspection ...

Отзывы: