2
5.2.1 Date&Time Setting
............................................................................................................... 17
5.2.2
Standard/Actual Test
............................................................................................................. 18
5.2.3
Bluetooth Setting
.................................................................................................................... 18
5.2.4 Printer Connecting
................................................................................................................ 18
5.2.5
Compensation K factor
......................................................................................................... 19
5.2.6 Input Current Temperature
................................................................................................. 19
5.3 Data Handling
.................................................................................................................................. 19
5.3.1
Scanning
5.3.2 Delete
...................................................................................................................................... 20
5.3.3 Print
....................................................................................................................................... 20
5.4 Data Output
...................................................................................................................................... 21
6.
Common Trouble Shooting
........................................................................................................................ 22
7.
Warranty and After Service
....................................................................................................................... 23
7.1 Warranty
.......................................................................................................................................... 23
7.2.
After Service
.................................................................................................................................. 23
Страница 1: ...del 6720 Instruction Manual Be sure to read this manual thoroughly before using the instrument Fully understand and pay attention to each caution mentioned Please keep this manual for ready reference...
Страница 2: ...ate of Purchase Month Day Year Attention 1 When the user receives the purchased instrument please fill in the warranty card carefully and confirm the signature then fax or send this form back to our c...
Страница 3: ...stallation 11 3 3 Pitot Tube Installation 11 3 4 Micromanometer Installation 11 4 Operation Directions 12 4 1 Supplying Power 12 4 2 On Off 13 4 3 Back Pressure Plate 13 5 Functions Test 13 5 1 Testin...
Страница 4: ...18 5 2 4 Printer Connecting 18 5 2 5 Compensation K factor 19 5 2 6 Input Current Temperature 19 5 3 Data Handling 19 5 3 1 Scanning 19 5 3 2 Delete 20 5 3 3 Print 20 5 4 Data Output 21 6 Common Troub...
Страница 5: ...le 1 AA batteries 4 Calibration certificate 1 CD Rom Manual and software inside 1 Quick Guide 1 Capture Hood 6720 Optional components Items Specifications 610 610mm Spare Hood 610 1220mm 305 1220mm 91...
Страница 6: ...ase 1 Pressure tubing 2 Communication cable 1 AA batteries 4 Calibration certificate 1 CD Rom Manual and software inside 1 Quick Guide 1 6720 DP Optional Parts Items Specifications 2 3 200mm Pitot Tub...
Страница 7: ...items Specific prohibited content is drawn in a circular frame This symbol indicates a mandatory action A specific action is given near the symbol WARNING Heating Forbidden Never bring the fabric hood...
Страница 8: ...ly When using an external power adapter ensure to use the correct power adapter as required Otherwise it may damage the instrument Forbidden Do not wipe the instrument with a volatile solvent The body...
Страница 9: ...7...
Страница 10: ...g and data transferring available Can be connected to a Bluetooth printer which is to print test data in real time Low power consumption Battery power supply can work continuously for 14 hours But if...
Страница 11: ...t Approx 3 6kg 2 Capture Hood Structure 2 1 Instrument Base 1 The exterior structure of the base 2 The internal structure of the base 3 Grid Frame poles Grid B Measuring point for air flow Micro manom...
Страница 12: ...exactly as shown Figure 3 to ensure a good fit 2 Use the 4 positioning holes on the base stitching as a guide to ensure the hood fully wraps around the base 2 Frame poles installation 1 2 3 4 Front v...
Страница 13: ...he base number one by one 3 2 Velocity Grid Installation Air velocity testing can be achieved when micromanometer works together with the velocity Grid Note Mounting angle between the Grid and handle...
Страница 14: ...wered by 4 AA size batteries with the battery compartment cover open install the batteries please pay attention to the polarity of the batteries Alkaline battery or rechargeable Ni MH battery can be u...
Страница 15: ...OWER for two seconds and the instrument will turn off automatically 4 3 Back pressure plate Note 1 When testing in non back pressure mode please keep the back pressure plate 2 When the air flow is gre...
Страница 16: ...the current testing mode 8 Wind direction icon 9 Test tool 10 Power supply mode display the current power supply 11 Bluetooth Status 12 Connecting the Bluetooth printer 5 1 1Single Measurement Mode N...
Страница 17: ...the time set by Cycle Per and the Cycle will increase automatically 5 Press STOP testing stop 6 Same testing method with the capture hood when using the Velocity Grid Pitot Micromanometer 5 1 3 Back P...
Страница 18: ...Bluetooth printer Note 1 Please purchase our dedicated Bluetooth printer and the printer icon will be displayed in the status bar after the connection is successful 2 In single test and back pressure...
Страница 19: ...itot tube correction factor 6 K Factor Test value correction factor 7 Cycle Per Data storage cycle 8 Damp Per Damping coefficient 9 Temp temperature input with tools of grid and pitot tube 5 2 1 Date...
Страница 20: ...differential pressure the function will be forbidden 5 2 3 Bluetooth Setting Note 1 Bluetooth communication is to realize the remote control and data monitoring of the air volume cover 6720 by using...
Страница 21: ...to compensate the test value to make it more accurate its range is 0 500 1 500 Note K Factor affects the accuracy of the measured value must have a test benchmark please use it with caution Example Se...
Страница 22: ...cycle Note 1 Only the data under the current tool is allowed to be deleted 2 Once the data is deleted it cannot be recovered 3 Please delete invalid data in time to ensure effective storage space 5 3...
Страница 23: ...he export function is to transfer the saved test data to the computer It needs to be used together with the communication cable and data acquisition software provided by our company Please refer to th...
Страница 24: ...1 in Manual Low or dead battery power Replace the batteries Temp Value 0 0 Humidity Value 0 0 Base s cable falls off Reinsert the connecting cable Sensor or cable is broken Connect after service for m...
Страница 25: ...quality problem the warranty will be one year from the date of product purchase 7 2 After Service When you have a problem with your instrument please check out the 6 Common Trouble Shooting section f...
Страница 26: ...24...
Страница 27: ...4 23898417 820 URL www kanomax com cn USA Kanomax Group Companies KANOMAX USA INC 219U S Highway 206 Andover New Jersey 07821 Tel 1 800 247 8887 USA 1 973 786 6386 FAX 1 973 786 7586 URL www kanomax u...