background image

    

 Thermo-Hygrometer

Model 6841

Read this manual carefully and understand the warnings before using this instrument.

Kanomax Japan, Inc.

Keep this manual in a safe place for your quick reference.

                                                       

  

Operation Manual

 

Содержание 6841

Страница 1: ...ermo Hygrometer Model 6841 Read this manual carefully and understand the warnings before using this instrument Kanomax Japan Inc Keep this manual in a safe place for your quick reference Operation Manual ...

Страница 2: ...Thank you for purchasing this Kanomax product Please use this instrument properly by reading the instruction manual and following the warning instructions ...

Страница 3: ...Name and function of parts Main body 1 Names and Functions of Parts Probe 2 Preparation for Measurement 3 Measurement 4 Battery Indicator 5 Unit Change 5 Specifications 6 Troubleshooting 7 Warranty and Service 8 ...

Страница 4: ...re Symbols symbol indicates a condition that requires caution The subject of each caution is illustrated inside the triangle Left caution for hot surface symbol indicates prohibition Do not take a prohibited action shown inside or near this symbol Left Do not disassemble This symbol indicates a mandatory action A specific action is given near the symbol DANGER Never expose the sensor to a flammabl...

Страница 5: ...Set batteries in the correct direction Check polarity Setting the batteries in the wrong direction may cause leakage and contaminate the Insert correctly instrument Do not wipe the instrument with a solvent The body may deform or deteriorate Use soft dry cloth to remove stains If stains persist soak the cloth in a neutral detergent and wipe the instrument with the soft cloth Do not use solvents su...

Страница 6: ...re than one second until the LCD is turned on For functions slide the switch down to change temperature and humidity parameters Humidity Temperature Humidity Sliding the switch upward has no function Approx 120 mm 4 7 Approx 34 mm 1 3 Approx 60 mm 2 4 Power Function Switch Battery Case Display Push and hold for more than one second Slide down to change between temperature and humidity ...

Страница 7: ... 2 Names and Functions of Parts Probe Humidity and temperature sensors are built in Sensor Grip Approx φ19 mm 0 75 Cable Length Approx 1 500 mm 59 Approx φ3 3mm 0 13 Approx 170 mm 6 7 ...

Страница 8: ...es are used charge them on an appropriate charger Slide the cover of the battery case down along the rail When it stops pull up the cover Insert batteries in the correct direction Check polarity Put the cover back by reversing the steps and When closing the battery case do not try to hook the cover or the cover may be damaged Make sure to slide the cover on the rail 1 2 3 4 ...

Страница 9: ...C thereby ensuring high accuracy Thermo Hygrometer is an electronic hygrometer which is known to have greater stability and shorter response time compared to conventional Assmann psychrometers Electronic hygrometers are also independent from external conditions while Assmann psychrometers are easily affected by factors such as dust dew and how the gauze is wrapped For more information on proper ha...

Страница 10: ...the voltage falls below 4 0V the LCD will shut down Turn off the power switch If Ni Cd batteries are used charge them before the indicator shows the 4 0 to 4 3V range Unit Change Temperature units can be changed between Celsius and Fahrenheit with a dip switch in the battery case SW2 is not used Units 1 2 OFF More than 4 6V Less than 4 0V 4 3V to 4 0V 4 6V to 4 3V 1 SW No F OFF ON factry default ...

Страница 11: ...e Cable Approx φ3 3 mm x 1 5 m 0 13 4 9 Main Body Approx 60 W x 120 L x 34 D mm 2 4 x 4 7 x 1 3 Power Four AA batteries Mn Alkali or Ni Cd use appropriate charger for Ni Cd batteries Battery Life Approx 45 hours with alkali batteries Probe 20 to 45 4 to 113 ゚F Operating Environment Main Body 5 to 40 41 to 104 ゚F Storage Environment 10 to 50 14 to 122 ゚F Weight Approx 180 g 6 3 oz Standard Accessor...

Страница 12: ...ing does not change Probe cable is damaged Contact a local distributor Out of the range Measure within the range Temperature sensor is damaged Contact a local distributor Temperature reading is set To 48 0 or temperature reading does not change Probe cable is damaged Contact a local distributor Batteries are depleted Replace with new batteries Battery Indicator blinks Battery terminals are unclean...

Страница 13: ...ng by the owner alteration accident electrical current fluctuations failure to follow operating or environmental instructions prescribed in the operation manual provided by Kanomax or service performed by other than Kanomax Service Whenever this product malfunctions check Troubleshooting and identify the possible causes Repair parts are stored for the minimum of five years after the production is ...

Отзывы: