INSTALLATION MANUAL / USER MANUAL
REMOTE CONTROL PANELS RC200 / RC200 NVG
PAGE: 14
OCT 03/2013
Press the switch downwards for at least 1 second then release it (the
switch comes back in ARMED position):
The visual indicator is flashing as follows:
• one short flash at the beginning of the self-test sequence
After a few seconds, the test result is displayed with the visual indicator
as follows:
• one long flash indicates the system is operational and that no error
conditions were found;
• a series of short flashes indicates the test has failed:
Refer to the ELT manual.
(2) RESET
This mode is used to stop the ELT when activated.
If the ELT is activated, the visual indicator of RCP is flashing in the same
way than the one of the ELT:
• Press the switch downwards for at least 1 second then release it (the
switch comes back in ARMED position):
• The visual indicator is OFF.
Important notice: On ELTs P/N S182X502-XX, if a RESET is
performed from RCP with the ELT manually activated (ON position
on the front panel of the ELT), the ELT transmission will stop for
max. 50 seconds then start again.
In this case, on the RCP:
• The led is off for max. 50 seconds then flash again.