INSTALLATION MANUAL OPERATION MANUAL INSPECTION LOG
KANNAD 406 AF-COMPACT
PAGE: 111
FEB 01/2008
(c) Weight
Approx. 40 gr. (0.088 lbs).
(2) Electrical Characteristics
The RC200 RCP is energized by the ELT when the ELT’s switch is on
ARM position.
- Switch:
• ON / ARM / RESET-TEST 3-position switch.
• Type of contacts: alloyed silver.
• Conductive material: Silver-plate alloyed copper.
• RESET: unstable position
- Led annunciator:
• Color: red.
• Peak - Wavelength: 635 nm.
• Viewing angle: 50 degrees.
(3) Electrical Interfaces
A single male 9-pin D-SUB connector (J1) enables to connect the RC200
remote control panel to the KANNAD 406 AF-COMPACT with a 3-wire
cable (AWG 24, shielded recommended).
On the ELT side, the wires are soldered to a male DIN 12 connector.
On the RCP side, the wires are connected to a female 9 pin D-SUB
connector.
Note: (1) RCP buzzer functionnality not featured by this model.
Table 2: J1, D-SUB 9 Pts Male Pin-out
Sub-D 9 Pts Male
Signal name
Destination
Viewed from
Front Face
1
Not used with KANNAD AF Compact
2
RCP BUZZER
(1)
ELT
3
BUZZER GND
(1)
BUZZER
4
RCP RESET
ELT
5
RCP ON
ELT
6
Not used with
KANNAD 406 AF-Compact
7
8
RCP COMMON
ELT
9
RCP LED
ELT