11
VW-SP1X44K
COMMAND
DESCRIPTION
PARAMETER
SBV N1
Set TV Wall Vertical Bezel
Correction
N1=0~255
RBEZ
Request Current Bezel
Correction State
NONE
SBEZ N1
Set Bezel Correction
Enable/Disable
N1=0(Off), 1(On)
RMDN
Request Unit ID Number
NONE
SMDN N1
Set Unit ID Number to N1
N1=0~255
SWDE
Reset All TV Wall Settings
NONE
SHOT N1
Fast Setting TV Wall Format
from Hotkey N1
N1=
0(1x1)
, 1(2x2), 2(3x3),
3(4x4), 4(5x5), 5(6x6),
6(2x3), 7(3x2), 8(3x4),
9(4x2), 10(4x3), 11(4x5),
12(1x2), 13(2x1), 14(1x3),
15(3x1), 16(1x4), 17(4x1),
18(2x4), 19(3x5), 20(5x4),
21(5x3), 22(6x2), 23(6x3)
SFAVE N1
Save Current TV Wall
Settings to N1
N1=1~5
RFAVE N1
Recall TV Wall Settings
from N1
N1=1~5
Note:
1.
All the RS-232 command will be not executed unless followed with a carriage
return. All commands are insensitive.
2.
RS-232 control is set to single device only, not for use with
Cascade/Bypass output's connection device.
3.
Bold values are the default settings.