Compact Scaler Switcher (with PoE)
23
Command
Function
Feedback Example
50911%
Exit command
CEC cmd: exit
4.4.4 Control Compact Scaler Switcher or 3rd Party Device from Local
Firstly, connect the RS232 port of the compact scaler switcher to RS232 port of PC.
Secondly, send command
50787%
(serial control mode 1, factory default) via RS232
communication software.
Lastly, send the right command of the compact scaler switcher or other remote RS232
device connected in present system. Connect as shown below:
Note:
1.
Turn on/ off HDCP auto-management by sending serial commands.
a)
When HDCP is set to “active,” whether the output source has HDCP
depends on the input source. If the input source has HDCP, so will the
output and vice versa.
b)
When HDCP is set to Manual, whether the output has HDCP depends
on the statue of HDCP. If you turn off HDCP, then the output will not
have HDCP and vice versa.
2.
Screen output adjustment avails only when the screen output adjusting is on.
Send command 50678% to turn on.
3.
CEC commands with grey background avails only when CEC is on.
4.
MIC precedence: In Mute mode, if the MIC noise detecting is on, the device
will unmute MIC automatically given the outer noise exceeds the limit of noise
detecting. Send 50696% to enable MIC precedence, then the device will not
be able to change the mute mode no matter how loud the noise is.
Содержание HDSC51HDBT