background image

LED on

LED off

Note: The continuity test is only possible when

batteries are installed & in good condition 

5. Continuity Test

The continuity test is only possible when 

batteries are inserted & in good condition.

Ensure the circuit under test is not live.

Connect test probes L1 and L2 to the circuit. The 

continuity LED (6) will illuminate & the buzzer will 

sound.

The unit will indicate continuity below 400K ohm.

LED on

LED off

Correct Phase Sequence 

Phase Rotation Test

Rotary Phase of 

Three-Phase Mains

6. Phase Rotation Indication

Perform a function test prior to this test.
This unit can determine the phase rotation within 

a three phase supply.

Connect test probe L2 to the supposed phase 

2 & the test probe L1 to the supposed phase 1. 

If the R LED illuminates the phases are in the 

correct sequence 1 to 2.

Connect test probe L2 to the supposed phase 3 

& test probe L1 to the supposed phase 2. 

If the R LED illuminates the phases are in the 

correct sequence 2 to 3.

Connect test probe L2 to the supposed phase 

1 & the test probe L1 to the supposed phase 3. 

If the R LED illuminates the phases are in the 

correct sequence 3 to 1.

During phase rotation test touch the contact 

electrode.

If the L LED illuminates, then the phase sequence 

is anti-clockwise.

LED on

LED off

Incorrect Phase 

Sequence 

6. Phase Rotation Indication (continued)

11

12

Содержание KANE-VCT

Страница 1: ...EN 61010 1 CAT IV 600V Instruction Manual KANE VCT Voltage Continuity Tester Voltage Indication 12 690V AC DC with Continuity Inventory No MAN00160 Rev 1 0221 February 2021...

Страница 2: ...this instrument is assured when operated within the specifications in this instruction manual The product identified above conforms to the requirements of council directive 2014 35 EU Contents I Overv...

Страница 3: ...ified nominal voltages The different indicating signals of the voltage indicator are not to be used for measuring purposes Before using a voltage indicator at locations with a high background noise le...

Страница 4: ...requested to thoroughly read the instruction manual comply with it in all sections III Instrument Symbols continued IV KANE VCT Specification 5 6 CAT IV Applicable to test measuring circuits connecte...

Страница 5: ...7 LCD for voltage display only DL6790 8 Contact electrode for double pole test of phase rotation single pole test 9 Torch button on the back 10 Positive LED 11 Negative LED 12 Battery Compartment AC...

Страница 6: ...a function test prior to this test This unit can be used as a single pole voltage indicator when the batteries are inserted The single pole test is intended only as a quick check The circuit must be...

Страница 7: ...s test This unit can determine the phase rotation within a three phase supply Connect test probe L2 to the supposed phase 2 the test probe L1 to the supposed phase 1 If the R LED illuminates the phase...

Страница 8: ...KANE s discretion This warranty covers normal use does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse abuse neglect or improper maintenan...

Страница 9: ...NE and the KANE logo registered in the UK and elsewhere are trademarks of Kane Group Limited used under licence All other marks are trademarks of their respective holders 2021 Kane International Limit...

Отзывы: