Diode

GOOD DIODE

Open Circuit Voltage

Overload Protection

Approx.: <3.0V DC

600V

• F

orward voltage drop if forward biased.

• “

OL” if reverse biased.

Features:  

MIN/MAX

 

HOLD

 

 

BAD DIODE

'0' Both directions (shorted)

or

V

Apo

V

Apo

Open Diode

Displays "OL" 

Both directions

RANGE

SEL

MIN/MAX

HOLD

FAST

V

Apo

A

µA

mAµA

A

mA

  10A

MAX

FUSED

  400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

DM505

A

µA

mA

Apo

V

Forward Bias

Displays 

approx. 

voltage drop

Features:  

RANGE

 

MIN/MAX

 

HOLD

 

 

AC VOLTS
Ranges

Accuracy

Resolution

Overload Protection

10nF to 9999µF

±(3.0%   +5 dgts)

0.01nF to 1µF

600V

Capacitance

RANGE

SEL

MIN/MAX

HOLD

FAST

V

Apo

A

µA

mAµA

A

mA

  10A

MAX

FUSED

  400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

DM505

A

µA

mA

Apo

AT

nF

 

 

WARNING

To avoid damaging the meter or euipment under test, safely discharge Capacitors before measuring capacitance. 

Large value capacitors should be discharged through an appropriate Resistance load. Use the DC Voltage function 

to confirm the capacitor discharge.

KANE505

®

KANE505

®

www.

.com

[email protected]

1.800.561.8187

Содержание 505

Страница 1: ...FAST V Apo A A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V INSTRUCTION MANUAL ENGLISH 1000V CAT II 600V CAT III KANE505 1000V Digital Multimeter KANE505 www com information...

Страница 2: ...BOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 AC DC Microamps 6000 A 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10 Test Lead Notes 10 Batt...

Страница 3: ...ge OL is displayed Dimensions 6 50 x 3 31 x 2 28 Item Weight 15 2 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications cETLus UL 61010 1 2012 3rd CE EN 61010 1 2010...

Страница 4: ...ys adhere to national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a c...

Страница 5: ...ress and hold to return to live readings E Select Button Press to select AC DC or Auto Selection in the following functions Voltage A mA Amps F Function Dial Turns on meter and is used to select the f...

Страница 6: ...s DC RMS at either the common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A mA 10A MAX FUSED 400mA MAX FUSED M...

Страница 7: ...tion Approx 1 0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A mA 10A M...

Страница 8: ...voltage drop Features RANGE MIN MAX HOLD AC VOLTS Ranges Accuracy Resolution Overload Protection 10nF to 9999 F 3 0 5 dgts 0 01nF to 1 F 600V Capacitance RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A...

Страница 9: ...2 5 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA 1 0 3 dgts 0 01mA to 0 1mA 600mA 10...

Страница 10: ...mA A Apo AT A Test Lead Notes CATIII 1000V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CATIV shield increases arc flash risk CATII 1000V Measurement...

Страница 11: ...communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can...

Страница 12: ...age expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when re...

Отзывы: