13.  Printouts 

 

 

 

 

 

 

KANE457    V 1.00G 
 
SERIAL NO. 000000000 
 
YOUR COMPANY NAME &              
PHONE NUMBER HERE 

KANE457     V 1.00G 
 
SERIAL NO. 000000000 
 
YOUR COMPANY NAME &              
PHONE NUMBER HERE 

KANE457     V 1.00G  
 
SERIAL NO. 000000000 
 
YOUR COMPANY NAME &              
PHONE NUMBER HERE 

 

 

 

DATE 

01/07/14 

PRESSURE 

DIFF TEMP 

TIME 

12:00:08 

 

 

 

 

DATE 

01/07/14 

DATE 

01.07/14 

COMBUSTION 

TIME 

12:00:08 

TIME 

12:00:08 

 

 

 

 

 

 

FUEL 

 

NAT GAS 

 

PRS 

mbar 

-0.037 

 

T1 

o

60.1 

O2 

5.4 

 

 

 

T2 

o

47.0 

CO2 

8.8 

 

 

 

∆T 

o

13.1 

CO 

ppm 

12 

 

Customer 

 

 

FLUE 

o

55.1 

 

 

 

 

INLT 

o

17.2 

 

Appliance 

 

Customer 

NETT 

o

37.9 

 

 

 

 

 

 

 

 

Ref. 

 

Appliance 

EFF 

(C) 

98.3 

 

 

 

 

LOSSES 

 

1.7 

 

 

 

Ref. 

XAIR 

34.8 

 

 

 

 

----------------------------------------------------- 

 

 

 

 

C a l .   d u e   o n   0 1 / 0 7 / 1 5 

 

 

 

 

----------------------------------------------------- 

 

KANE457     V 1.00G 
 
SERIAL NO. 000000000 
 
YOUR COMPANY NAME &              
PHONE NUMBER HERE 
 

 

 

CO/CO2 

 

0.0001 

 

 

 

 

 

 

 

 

KANE457     V 1.00G 
 
SERIAL NO. 000000000 
 
YOUR COMPANY NAME &              
PHONE NUMBER HERE 
 

PRS 

mbar 

0.00 

 

 

 

 

 

 

 

 

 

Customer 

 

ROOM AIR TEST 

 

 

 

 

 

 

Appliance 

 

LOG 

01 

 

LOG 

01 

 

 

DATE 

01/07/14 

 

DATE 

01/07/14 

Ref. 

 

TIME 

12:00:08 

 

TIME 

12:00:08 

 

 

 

 

 

 

 

 

TEST 

CO ppm 

CO2 ppm 

 

LET BY TEST 

 

 

 

 

 

 

222 

 

PRS-1 

mbar 

10.12 

KANE457    V 1.00G 
 
SERIAL NO. 000000000 
 
YOUR COMPANY NAME &              
PHONE NUMBER HERE 

 

192 

 

PRS-2 

mbar 

10.11 

 

177 

 

LET-BY 

MINS 

1:00 

 

178 

 

 

 

 

 

183 

 

TIGHTNESS TEST 

 

189 

 

 

 

192 

 

PRS-1 

mbar 

20.12 

AMBIENT CO/CO2 

 

200 

 

PRS-2 

mbar 

20.10 

 

 

15 

235 

 

∆PRS 

mbar 

-0.02 

DATE 

01/07/14 

 

 

 

STABIL’N 

MINS 

1:00 

TIME 

12:00:08 

 

MAXIMUM CO 

 

TIGHTN’S 

MINS 

2:00 

 

 

MAXIMUM CO2 

235 

 

 

 

 

CO ppm 

 

 

 

Customer 

CO2 ppm 

223 

 

Customer 

 

 

MAXIMUM CO 

 

 

 

Appliance 

MAXIMUM CO2 

223 

 

Appliance 

 

 

 

 

 

 

Ref. 

Customer 

 

Ref. 

 

 

 

 

 

 

 

Appliance 

 

 

 

 

 

 

 

 

 

Ref. 

 

 

 

 

 

Содержание 457

Страница 1: ...CKLIGHT Switches backlight torch light ON OFF PUMP Turns the pump ON OFF Hold button to zero pressure SEND ENTER Send readings to printer Press button for 1 second Send readings to memory Hold button...

Страница 2: ...connection Flue Gas Inlet Watertrap Drain with Red Screw Plug Flue probe temperature T1 Inlet temperature T2 Pressure connection P1 Pressure connection P2 differential Fit Spigot to Hose before connec...

Страница 3: ...ection 11 Current date Can be set via the Menu see section 11 Number of days until re calibration is required Note Boiler inlet air temperature can either be a Set automatically by the flue probe duri...

Страница 4: ...o zero the pressure sensor Using the black connectors and manometer hose connect to P1 for single pressure or P1 and P2 for differential pressure PRS display PRESSURE P 0 04 mbar 12 56 29 Defaults to...

Страница 5: ...an be printed immediately or later from the memory Note The analyser s memory can store up to 20 tightness tests Tightness tests are logged automatically therefore the tightness section of the memory...

Страница 6: ...om CO test is automatically stored as a log number Ambient CO2 CO ideal for walk around testing COp 8 CO2P 900 COx 14 CO2x 985 Real time CO reading ppm Real time CO2 reading ppm Maximum CO reading ppm...

Страница 7: ...that avoids the 90 second countdown With the KANE457 switched off press and hold down and then press and release Release after MANO_MOD is displayed on top line The KANE457 will now operate as a fixed...

Страница 8: ...1111 REPORT COMB N Stored combustion tests VIEW DEL ALL or EXIT max 99 tests SCREEN CONTRAST Factory setting is 04 AUX Enables users to customise the parameters on the AUX display User can set any pa...

Страница 9: ...duration of tightness test in minutes Default 2 minute EXIT REPORT PRESSURE Stored pressure tests VIEW DEL ALL or EXIT max 20 tests TIGHTN S Stored let by and tightness tests VIEW DEL ALL or EXIT 20 t...

Страница 10: ...Stored Amb CO2 CO tests VIEW DEL ALL or EXIT 20 tests TIMED Stored Timed Logs VIEW DEL ALL or EXIT 20 tests SCREEN CONTRAST Factory setting is 04 AUX Enables users to customise the parameters on the A...

Страница 11: ...0G SERIAL NO 000000000 YOUR COMPANY NAME PHONE NUMBER HERE CO CO2 0 0001 KANE457 V 1 00G SERIAL NO 000000000 YOUR COMPANY NAME PHONE NUMBER HERE PRS mbar 0 00 Customer ROOM AIR TEST Appliance LOG 01 L...

Страница 12: ......

Страница 13: ...tle Company Name Company Address 1 Address 2 Town City County Postcode Country Phone Number Fax Number Mobile Number Email Address Product Details Note Proof of Purchase may be required for warranty c...

Страница 14: ...ecommendation Internet Search Exhibition Other Which do you read most often Often Sometimes Hardly Ever Registered Gas Engineer Gas Installer P H P I P H A M News Heating Ventilating Plumbing Heating...

Страница 15: ......

Страница 16: ...ying this analyser Before use please register on our website www kane co uk Scan the QR code to go directly to Register your Product on line or complete detach and return the Product Registration form...

Отзывы: