KANE425
manual
Page
19
4.5 ROOM
CO
TESTING
Select “Room CO” for CO investigations.
Press
to start the 15 minute duration room CO test.
ROOM CO display
ROOM
CO
→
When complete the room CO test is
automatically stored in the memory
CO
00
→
Real time CO reading (ppm)
TEST
00
→
Test 00 = initial reading
Test 15 = final reading
LOG
01
→
The log number for the test is displayed.
Press
to print the room CO test (also sends to PC if Bluetooth fitted)
Viewing / printing a logged Room CO test
Select MENU / REPORT / ROOM CO / VIEW
Use
or
to select the log number to be viewed / printed.
Use
to view individual readings.
Hold
for 2+ seconds to print the test (also sends to PC if Bluetooth
fitted).
NOTE: To abort a room CO test move the rotary switch to any position
other than “Room CO”.
NOTE: The “AUX” display can be used to time and manually record ambient
CO levels to comply with BS7967 – see Page 14.